Comparative hemolytic effectiveness of 1 MHz ultrasound on human and rabbit blood in vitro

被引:8
作者
Abramowicz, JS
Miller, MW
Battaglia, LF
Mazza, S
机构
[1] Univ Rochester, Sch Med & Dent, Dept Obstet & Gynecol, Rochester, NY 14642 USA
[2] Univ Chicago, Dept Obstet & Gynecol, Chicago, IL 60637 USA
关键词
cell size; sonolysis in vitro; intraspecies comparison;
D O I
10.1016/S0301-5629(03)00034-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This project continued testing of the general working hypothesis that cell size is a physical determinant in extent of ultrasound (US)-induced hemolysis, the larger the cell the greater the lysis. For this project, the specific hypothesis tested was that human erythrocytes, being larger than rabbit erythrocytes, would be the more sensitive to sonolysis induced by inertial cavitation in the presence of Albunex(R), a US contrast agent. The rationale behind this hypothesis was 1. an earlier-published analytic construct indicating an inverse relation between particle size and the shear force required for deformation, and 2. a number of independent demonstrations that, among sized populations of erythrocytes, an inverse relation exists between erythrocyte volume and mechanically-induced shear forces in the cell-bathing medium; namely, the larger the cell, the less shear force required to rupture the cell's membrane. The present data support the hypothesis; over six independent trials, the mean corpuscular volumes of human (H) and rabbit (R) erythrocytes were 89.5 and 64.1 mum(3), respectively, H > R (p < < 0.001), and the ratio of US-induced hemolysis in H to R blood in vitro was 1.12:1.0 (p < 0.004). (C) 2003 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:867 / 873
页数:7
相关论文
共 24 条
[1]  
*AIUM, 2003, IN PRESS DIAGN ULTR
[2]   Temporality in ultrasound-induced cell lysis in vitro [J].
Azadniv, M ;
Doida, Y ;
Miller, MW ;
Brayman, AA ;
Meltzer, RS .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (01) :45-55
[3]   Hemolysis of albunex-supplemented, 40% hematocrit human erythrocytes in vitro by 1-MHz pulsed ultrasound: Acoustic pressure and pulse length dependence [J].
Brayman, AA ;
Azadniv, M ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :927-938
[4]   Hemolysis of 40% hematocrit, Albunex(R)-supplemented human erythrocytes by pulsed ultrasound: Frequency, acoustic, pressure and pulse length dependence [J].
Brayman, AA ;
Strickler, PL ;
Luan, H ;
Barned, SL ;
Raeman, CH ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1237-1250
[5]   LYSIS OF ERYTHROCYTES BY EXPOSURE TO CW ULTRASOUND [J].
CARSTENSEN, EL ;
KELLY, P ;
CHURCH, CC ;
BRAYMAN, AA ;
CHILD, SZ ;
RAEMAN, CH ;
SCHERY, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) :147-165
[6]  
Drabkin DL, 1932, J BIOL CHEM, V98, P719
[7]   Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro [J].
Everbach, EC ;
Makin, IRS ;
Azadniv, M ;
Meltzer, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (04) :619-624
[8]   TRANSIENT PULSATIONS OF SMALL GAS-BUBBLES IN WATER [J].
FLYNN, HG ;
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (03) :985-998
[9]  
Jain N.C., 1986, Schalm's veterinary hematology
[10]   Lack of bioeffects of ultrasound energy after intravenous administration of FS069 (Optison) in the anesthetized rabbit [J].
Killam, AL ;
Greener, Y ;
McFerran, BA ;
Maniquis, J ;
Bloom, A ;
Widder, KJ ;
Dittrich, HC .
JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (06) :349-356