摘要
A small pixellated gamma-ray detector has been constructed from a 5 mm thick CdZnTe substrate and characterized for spectroscopic and spatial properties. Emphasis has been placed on revealing 'pixel-level' results to further understand optimum array design and operation. The anode design is (1.5x1.5) mm(2) pixels on a 1.625 mm pitch. Spectroscopic results with a Co-57 source display an average energy resolution of 3.9 keV FHWM. Analysis of the electronic noise for different pixels showed good agreement with a theoretical model, and similar performance between edge and interior pixels. A test of spatial response with incident radiation scanned across the anode face show good agreement with the pixel geometry and an undetectable amount of dependance on interaction depth.
引用
收藏
页码:417 / 420
页数:4
相关论文
共 9 条
[1]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[2]  
BENNETT KS, 1997, NUCL INSTRUM METH A, V392, P260
[3]   PROPERTIES OF CDZNTE CRYSTALS GROWN BY A HIGH-PRESSURE BRIDGMAN METHOD [J].
DOTY, FP ;
BUTLER, JF ;
SCHETZINA, JF ;
BOWERS, KA .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (04) :1418-1422
[4]  
Eskin J. D., 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (Cat. No.95CH35898), P544, DOI 10.1109/NSSMIC.1995.504320
[5]   A PROTOTYPE HIGH-PURITY GERMANIUM DETECTOR SYSTEM WITH FAST PHOTON-COUNTING CIRCUITRY FOR MEDICAL IMAGING [J].
HASEGAWA, BH ;
STEBLER, B ;
RUTT, BK ;
MARTINEZ, A ;
GINGOLD, EL ;
BARKER, CS ;
FAULKNER, KG ;
CANN, CE ;
BOYD, DP .
MEDICAL PHYSICS, 1991, 18 (05) :900-909
[6]   Progress in the development of large area sub-millimeter resolution CdZnTe strip detectors [J].
Macri, JR ;
Boykin, DV ;
Larson, K ;
Mayer, M ;
McConnell, ML ;
Ryan, JM ;
Cherry, ML ;
Guzik, TG ;
Apotovsky, BA ;
Butler, JF ;
Doty, FP ;
Lingren, CL .
HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 :29-36
[7]   A 48x48 CdZnTe array with multiplexer readout [J].
Marks, DG ;
Barber, HB ;
Barrett, HH ;
Dereniak, EL ;
Eskin, JD ;
Matherson, KJ ;
Woolfenden, JM ;
Young, ET ;
Augustine, FL ;
Hamilton, WJ ;
Venzon, JE ;
Apotovsky, BA ;
Doty, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1253-1259
[8]  
MAYER M, 1996, 1996 IEEE NUCL SCI S, P803
[9]   ELECTRONIC NOISE IN LEAD IODIDE X-RAY-DETECTORS [J].
SHAH, KS ;
LUND, JC ;
OLSCHNER, F ;
BENNETT, P ;
ZHANG, J ;
MOY, LP ;
SQUILLANTE, MR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :85-88