Surface structure of polycarbonate urethanes visualized by atomic force microscopy

被引:42
作者
Revenko, I
Tang, Y
Santerre, JP
机构
[1] Digital Instruments, Santa Barbara, CA 93117 USA
[2] Univ Toronto, Fac Dent, Toronto, ON M5S 1A8, Canada
关键词
atomic force microscopy; surface structure; morphology; roughness; and topography;
D O I
10.1016/S0039-6028(01)01298-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Polycarbonate polyurethanes are utilized for the production of long-term biomedical implants. The thermodynamic incompatibility between the hard and soft segments that make up these materials induces a two-phase microstructure. This two-phase structure (i.e. hard and soft segment phases) has unique features which contribute to its mechanical stability and moderate biocompatibility at the surface. As AFM was used to study the structure of six different polyurethane elastomers, where the reagent stoichiometrics, as well as the chemistry of the hard segments, were changed. The results (especially phase-mode images) indicated that the microdomain structures depend on the hard segment chemistry and are relatively less dependent on the stoichiometry. This type of data could be used in the future to relate biological responses to the surface architecture and chemistry of polyurethanes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:346 / 354
页数:9
相关论文
共 55 条
[21]  
Han DK, 1998, J BIOMAT SCI-POLYM E, V9, P667
[22]   EFFECT OF HARD SEGMENT CHEMISTRY AND STRAIN ON THE STABILITY OF POLYURETHANES - INVIVO BIOSTABILITY [J].
HERGENROTHER, RW ;
WABERS, HD ;
COOPER, SL .
BIOMATERIALS, 1993, 14 (06) :449-458
[23]  
Jänchen G, 1999, SURF INTERFACE ANAL, V27, P444, DOI 10.1002/(SICI)1096-9918(199905/06)27:5/6<444::AID-SIA531>3.0.CO
[24]  
2-3
[25]   Concentration dependence of crystallinity of polycarbonate by shock-cooling and subsequent freeze-drying of its various solutions [J].
Ji, GD ;
Xue, G ;
Ma, JL ;
Dong, CY ;
Gu, XH .
POLYMER, 1996, 37 (15) :3255-3258
[26]  
Kilpadi DV, 2000, INT J ORAL MAX IMPL, V15, P219
[27]   Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thicknesses [J].
Larsson, C ;
Thomsen, P ;
Aronsson, BO ;
Rodahl, M ;
Lausmaa, J ;
Kasemo, B ;
Ericson, LE .
BIOMATERIALS, 1996, 17 (06) :605-616
[28]  
Lelah M., 1986, Polyurethanes in Medicine
[29]   Fractal analysis of pharmaceutical particles by atomic force microscopy [J].
Li, TL ;
Park, K .
PHARMACEUTICAL RESEARCH, 1998, 15 (08) :1222-1232
[30]  
MacDonald DE, 1998, J BIOMED MATER RES, V41, P120