Fiber-packed channel bioreactor for microfluidic protein digestion

被引:35
作者
Fan, Huizhi [1 ]
Chen, Gang [1 ]
机构
[1] Fudan Univ, Sch Pharm, Shanghai 200032, Peoples R China
关键词
fiberglass; microchip; microreactors; trypsin;
D O I
10.1002/pmic.200700505
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fabrication and performance of a fiber-packed channel bioreactor in microchip along with its application in protein analysis were reported. The feasibility and performance of the unique microfluidic bioreactor were demonstrated by the tryptic digestion of myoglobin (MYO) and BSA. The on-chip digestion was carried out at a flow rate of 2.0 mu L/min and the digestion time was significantly reduced to less than 5 s. The digests were identified by MALDI-TOF MS with sequence coverages of 66% (MYO) and 40% (BSA) that were comparable to those obtained by the conventional in-solution tryptic digestion. The present fiber-based microchip bioreactor provides a promising platform for the high-throughput protein identification.
引用
收藏
页码:3445 / 3449
页数:5
相关论文
共 21 条
[1]   Immobilized metal-ion chelating capillary microreactor for peptide mapping analysis of proteins by matrix assisted laser desorption/ionization-time of flight-mass spectrometry [J].
Guo, Z ;
Xu, SY ;
Lei, ZD ;
Zou, HF ;
Guo, BC .
ELECTROPHORESIS, 2003, 24 (21) :3633-3639
[2]   Microfluidic assays of acetylcholinesterase inhibitors [J].
Hadd, AG ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5206-5212
[3]   Zeolite nanoparticle modified microchip reactor for efficient protein digestion [J].
Huang, Y ;
Shan, W ;
Liu, BH ;
Liu, Y ;
Zhang, YH ;
Zhao, Y ;
Lu, HJ ;
Tang, Y ;
Yang, PY .
LAB ON A CHIP, 2006, 6 (04) :534-539
[4]   On-chip proteolytic digestion and analysis using "wrong-way-round" electrospray time-of-flight mass spectrometry [J].
Lazar, IM ;
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1733-1739
[5]   Multi layer-assembled microchip for enzyme immobilization as reactor toward low-level protein identification [J].
Liu, Y ;
Lu, HJ ;
Zhong, W ;
Song, PY ;
Kong, JL ;
Yang, PY ;
Girault, HH ;
Liu, BH .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :801-808
[6]   Assembly-controlled biocompatible interface on a microchip: Strategy to highly efficient proteolysis [J].
Liu, Yun ;
Zhong, Wei ;
Meng, Sheng ;
Kong, Jilie ;
Lu, Haojie ;
Yang, Pengyuan ;
Girault, Hubert H. ;
Liu, Baohong .
CHEMISTRY-A EUROPEAN JOURNAL, 2006, 12 (25) :6585-6591
[7]   Thermal denaturation: A useful technique in peptide mass mapping [J].
Park, ZY ;
Russell, DH .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2667-2670
[8]   Enzymatic microreactor-on-a-chip:: Protein mapping using trypsin immobilized on porous polymer monoliths molded in channels of microfluidic devices [J].
Peterson, DS ;
Rohr, T ;
Svec, F ;
Fréchet, JMJ .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4081-4088
[9]   High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith coupled to MALDI TOF and ESI TOF mass spectrometers [J].
Peterson, DS ;
Rohr, T ;
Svec, F ;
Fréchet, JMJ .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (06) :563-568
[10]   Creation of an on-chip enzyme reactor by encapsulating trypsin in sol-gel on a plastic microchip [J].
Sakai-Kato, K ;
Kato, M ;
Toyo'oka, T .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :388-393