Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry

被引:14
作者
Greenfield, DS [1 ]
Knighton, RW [1 ]
Feuer, WJ [1 ]
Schiffman, JC [1 ]
机构
[1] Univ Miami, Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Palm Beach Gardens, FL 33418 USA
来源
OPHTHALMIC SURGERY LASERS & IMAGING | 2003年 / 34卷 / 02期
关键词
D O I
10.3928/1542-8877-20030301-17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the distribution of retinal nerve fiber layer thickness measurements in normal eyes corrected for corneal polarization axis (CPA). METHODS: Complete ocular examination, standard automated perimetry, peripapillary and macular scanning laser polarimetry imaging, and CPA measurements were performed in normal eyes. A noninvasive device mounted on a slit lamp that incorporated two crossed linear polarizers and an optical retarder to measure the slow axis of corneal birefringence was constructed. One eye per patient was enrolled. Exclusion criteria consisted of visual acuity of less than 20/40, a refractive error exceeding +/- 5.0 diopter sphere, 2.0 diopter cylinder, or both, previous intraocular surgery, or ocular disease except cataract. According to scanning laser polarimetry, peripapillary retardation parameters within 90% normal limits were recorded as "normal," parameters outside 95% normal limits were recorded as ''abnormal," and parameters between 90% and 95% limits were recorded as "borderline." RESULTS: Fifty-one eyes of 51 subjects (14 men, 37 women) were enrolled (mean age, 51 17 years). Prediction limits ( 2 standard deviation outside of regression line) were calculated for 14 peripapillary retardation parameters. The prediction limits of the average thickness of the retinal nerve fiber layer (pm) were reduced 35% by correction of the CPA; for ellipse average (mum), the limits were reduced 33%. Sixteen of 51 normal eyes (31%) had at least one abnormal retardation parameter, and among these 16 eyes there was a bimodal distribution of CPA values (00 to 200 nasally downward, 60degrees to 80degrees nasally downward). CONCLUSIONS: Correction for CPA reduces the variance of normal retardation measurements. Normal eyes with a CPA of 00 to 200 nasally downward and 60degrees to 80degrees nasally downward were characterized by "abnormal" summary retardation parameters as interpreted by scanning laser polarimetry.
引用
收藏
页码:165 / 171
页数:7
相关论文
共 33 条
[11]   Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Huang, XR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (06) :715-722
[12]   Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Feuer, WJ ;
Schiffman, JC ;
Zangwill, L ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) :27-33
[13]  
Hoh ST, 1999, J GLAUCOMA, V8, P159
[14]   Optical coherence tomography and scanning laser polarimetry in normal, ocular hypertensive, and glaucomatous eyes [J].
Hoh, ST ;
Greenfield, DS ;
Mistlberger, A ;
Liebmann, JM ;
Ishikawa, H ;
Ritch, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (02) :129-135
[15]  
Hoh ST, 1998, J GLAUCOMA, V7, P12
[16]  
Hoh ST, 1998, OPHTHALMIC SURG LAS, V29, P545
[17]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[18]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[19]  
Knighton RW, 2002, INVEST OPHTH VIS SCI, V43, P82
[20]  
Knighton RW, 2002, INVEST OPHTH VIS SCI, V43, P383