Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria

被引:33
作者
Asplund, Sara [1 ,2 ]
Johnsson, Ase A. [3 ]
Vikgren, Jenny [3 ]
Svalkvist, Angelica [1 ,2 ]
Boijsen, Marianne [3 ]
Fisichella, Valeria [3 ]
Flinck, Agneta [3 ]
Wiksell, Asa [3 ]
Ivarsson, Jonas [4 ]
Rystedt, Hans [4 ]
Mansson, Lars Gunnar [1 ,2 ]
Kheddache, Susanne [3 ]
Bath, Magnus [1 ,2 ]
机构
[1] Univ Gothenburg, Dept Radiat Sci, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Radiol, Gothenburg, Sweden
[4] Univ Gothenburg, Dept Educ Commun & Learning, Gothenburg, Sweden
关键词
Digital radiography; thorax; lung; adults; observer performance; SUBTLE LUNG NODULES; X-RAY TOMOSYNTHESIS; OBSERVER PERFORMANCE; CLINICAL-EXPERIENCE; IMAGE QUALITY; RADIOGRAPHY; NOISE; JAFROC; SOFTWARE; LOCATION;
D O I
10.1258/ar.2011.100378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Background: In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. Purpose: To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. Material and Methods: Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. Results: Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and subpleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. Conclusion: The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution.
引用
收藏
页码:503 / 512
页数:10
相关论文
共 40 条
[1]
Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation [J].
Bath, M. ;
Mansson, L. G. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (951) :169-176
[2]
Nodule detection in digital chest radiography:: Part of image background acting as pure noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Bochud, FO ;
Verdun, FR ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :102-108
[3]
Nodule detection in digital chest radiography:: Introduction to the radius chest trial [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Ruschin, M ;
Tingberg, A ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :85-91
[4]
Nodule detection in digital chest radiography:: Effect of anatomical noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Hoeschen, C ;
Tischenko, O ;
Kheddache, S ;
Vikgren, J ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :109-113
[5]
BATH M, 2010, RADIAT PROT DOSIM, V139, P37
[6]
Effective dose to patients from chest examinations with tomosynthesis [J].
Bath, Magnus ;
Svalkvist, Angelica ;
von Wrangel, Alexa ;
Rismyhr-Olsson, Heidi ;
Cederblad, Ake .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :153-158
[7]
A software tool for increased efficiency in observer performance studies in radiology [J].
Börjesson, S ;
Håkansson, M ;
Båth, M ;
Kheddache, S ;
Svensson, S ;
Tingberg, A ;
Grahn, A ;
Ruschin, M ;
Hemdal, B ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :45-52
[8]
BUNCH PC, 1978, J APPL PHOTOGR ENG, V4, P166
[9]
Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates [J].
Carlander, A. ;
Hansson, J. ;
Soderberg, J. ;
Steneryd, K. ;
Bath, M. .
ACTA RADIOLOGICA, 2008, 49 (04) :468-474
[10]
A status report on free-response analysis [J].
Chakraborty, D. P. .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :20-25