Performing enzyme-free H2O2 biosensor and simultaneous determination for AA, DA, and UA by MWCNT-PEDOT film

被引:230
作者
Lin, Kuo-Chiang [1 ]
Tsai, Tsung-Hsuan [1 ]
Chen, Shen-Ming [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Electroanal & Bioelectrochem Lab, Taipei 106, Taiwan
关键词
MWCNT; PEDOT; Hydrogen peroxide; Ascorbic acid; Dopamine; Uric acid; HYDROGEN-PEROXIDE; ELECTROCHEMICAL BIOSENSORS; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; COMPOSITE ELECTRODES; NANOWIRE ARRAYS; CARBON; GLUCOSE; SENSOR; HEXACYANOFERRATE;
D O I
10.1016/j.bios.2010.07.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
An enzyme-free hydrogen peroxide (H2O2) biosensor based on MWCNT-PEDOT film modified electrode has been successfully performed on glassy carbon electrode (GCE) and indium tin oxide (ITO) electrode. At an applied potential of -0.5 V vs. Ag/AgCl, the MWCNT-PEDOT electrode exhibited linearly dependence on H2O2 concentration in the range of 0.1-9.8 mM. It can be observed two significantly linear sections. One shows sensitivity of 943 mu M mM(-1) cm(-2) with signal/noise of 6; and the other one shows sensitivity of 174 mu M mM(-1) cm(-2) with signal/noise of 4 in pH 7 PBS. It also presented excellent stability at room temperature, with a variation of response current less than 5% over 30 days. Moreover, the sensor was characterized by cyclic voltammetry (CV), scanning electronic microscopy (SEM), atomic force microscopy (AFM), and different pulse voltammetry (DPV). This sensor also can simultaneously detect AA, DA, and UA and can be utilized to develop multifunctional biosensors. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:608 / 614
页数:7
相关论文
共 49 条
[1]
Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]
Control of the properties of carbon nanotubes synthesized by CVD for application in electrochemical biosensors [J].
Bustero, I ;
García, A ;
Obieta, I ;
Muñoz, R ;
Rincón, I ;
Arteche, A .
MICROCHIMICA ACTA, 2006, 152 (3-4) :239-247
[3]
Determination of hydrogen peroxide using glassy carbon and graphite/polyester composite electrodes modified by vanadium-doped zirconias [J].
Doménech, A ;
Alarcón, J .
ANALYTICA CHIMICA ACTA, 2002, 452 (01) :11-22
[4]
Polyelectrolyte stabilized oxidase based biosensors: effect of diethylaminoethyl-dextran on the stabilization of glucose and lactate oxidases into porous conductive carbon [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :67-73
[5]
Phosphate biosensor based on polyelectrolyte-stabilized pyruvate oxidase [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2001, 427 (02) :271-277
[6]
Groenendaal BL, 2000, ADV MATER, V12, P481, DOI 10.1002/(SICI)1521-4095(200004)12:7<481::AID-ADMA481>3.0.CO
[7]
2-C
[8]
POLY(ALKYLENEDIOXYTHIOPHENE)S - NEW, VERY STABLE CONDUCTING POLYMERS [J].
HEYWANG, G ;
JONAS, F .
ADVANCED MATERIALS, 1992, 4 (02) :116-118
[9]
HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[10]
Nanotechnology in clinical laboratory diagnostics [J].
Jain, KK .
CLINICA CHIMICA ACTA, 2005, 358 (1-2) :37-54