Polyelectrolyte stabilized oxidase based biosensors: effect of diethylaminoethyl-dextran on the stabilization of glucose and lactate oxidases into porous conductive carbon

被引:74
作者
Gavalas, VG [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Dept Chem, Analyt Chem Lab, Iraklion 71409, Crete, Greece
关键词
biosensor; porous carbon electrode; polyelectrolyte; operational stability;
D O I
10.1016/S0003-2670(99)00688-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The lifetime and the reproducibility of novel enzyme stabilizing techniques based on polyelectrolyte agents such as diethylamimoethyl-dextran have been studied. Glucose oxidase and lactate oxidase, used as the model enzymes, are stabilized with the cationic polyelectrolyte, and the resulting enzyme-polyelectrolyte complexes are physically adsorbed into a highly porous and conductive carbon electrode for the construction of the biosensors. The amounts of diethylaminoethyl-dextran and enzyme are optimized with respect to sensor's sensitivity and stability. Optimum results were obtained using soaking solutions of 2500 U/ml GOx and 1.0 w/v deae-dextran. Additionally, experiments with lactate oxidase sensors constructed using 200 U/ml LOx and 0.5% w/v deae-dextran solution showed improved operational, and storage stability. The sensor-to-sensor reproducibility was good, the relative standard deviation being less than 5.0%. (C)2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 37 条
[1]   High temperature stabilisation of immobilised glucose oxidase: potential applications in biosensors [J].
Appleton, B ;
Gibson, TD ;
Woodward, JR .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) :65-69
[2]  
Bergmeyer H.U., 1983, METHOD ENZYMAT AN, V2, P201
[3]   Amperometric biosensor with physically immobilized glucose oxidase on a PVA cryogel membrane [J].
Doretti, L ;
Ferrara, D ;
Gattolin, P ;
Lora, S .
TALANTA, 1997, 44 (05) :859-866
[4]  
EGGINS BR, 1996, BIOSENSORS INTRO, V87, P147
[5]   Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode [J].
Gavalas, VG ;
Chaniotakis, NA ;
Gibson, TD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1205-1211
[6]  
GIBSON TD, 1993, STUD ORG CHEM, V47, P337
[7]  
GIBSON TD, 1992, ACS SYM SER, V487, P40
[8]   EXTENDED SHELF-LIFE OF ENZYME-BASED BIOSENSORS USING A NOVEL STABILIZATION SYSTEM [J].
GIBSON, TD ;
HULBERT, JN ;
PARKER, SM ;
WOODWARD, JR ;
HIGGINS, IJ .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :701-708
[9]   STABILIZATION OF ANALYTICAL ENZYMES USING A NOVEL POLYMER CARBOHYDRATE SYSTEM AND THE PRODUCTION OF A STABILIZED, SINGLE REAGENT FOR ALCOHOL ANALYSIS [J].
GIBSON, TD ;
HIGGINS, IJ ;
WOODWARD, JR .
ANALYST, 1992, 117 (08) :1293-1297
[10]  
Gibson TD, 1996, DEV BIOLOGICALS, V87, P207