Phosphate biosensor based on polyelectrolyte-stabilized pyruvate oxidase

被引:55
作者
Gavalas, VG [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Dept Chem, Analyt Chem Lab, Iraklion 71409, Crete, Greece
关键词
recombinant pyruvate oxidase; phosphate; biosensor; polyelectrolyte; porous carbon electrode; serum analysis;
D O I
10.1016/S0003-2670(00)01204-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the development of a pyruvate oxidase-based phosphate biosensor is illustrated. The use of polyelectrolyte stabilized recombinant pyruvate oxidase in conjunction with a porous conductive carbon results in the development of a simple, reproducible and stable phosphate biosensor. The polyelectrolyte diethylaminoethyl-dextran or DNA was used as the enzyme stabilizer, and the resulting enzyme-polyelectrolyte complexes were physically adsorbed into the transducer, a highly porous and conductive carbon electrode, for the construction of the biosensor. The optimized biosensor exhibits high operational (67% remaining activity after 220 h) and storage (49% remaining activity after 24 weeks) stability, and very good sensor-to-sensor reproducibility. The optimized phosphate biosensor was used for the measurement of the phosphate ion activity in serum. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 30 条
[1]   High temperature stabilisation of immobilised glucose oxidase: potential applications in biosensors [J].
Appleton, B ;
Gibson, TD ;
Woodward, JR .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) :65-69
[2]   A bienzyme modified carbon paste electrode for amperometric detection of pyruvate [J].
Bergmann, W ;
Rudolph, R ;
Spohn, U .
ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) :233-241
[3]   A NOVEL ENZYME SENSOR FOR THE DETERMINATION OF INORGANIC-PHOSPHATE [J].
CONRATH, N ;
GRUNDIG, B ;
HUWEL, S ;
CAMMANN, K .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :47-52
[4]   An bienzyme electrode (alkaline phosphatase polyphenol oxidase) for the amperometric determination of phosphate [J].
Cosnier, S ;
Gondran, C ;
Watelet, JC ;
De Giovani, W ;
Furriel, RPM ;
Leone, FA .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3952-3956
[5]   Flow-injection determination of catechol with a new tyrosinase/DNA biosensor [J].
Dantoni, P ;
Serrano, SHP ;
Brett, AMO ;
Gutz, IGR .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :137-145
[6]   EFFECT OF ENZYME RATIO AND ENZYME LOADING ON THE PERFORMANCE OF A BIENZYMATIC ELECTROCHEMICAL PHOSPHATE BIOSENSOR [J].
DURSO, EM ;
COULET, PR .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :535-542
[7]   PHOSPHATE-SENSITIVE ENZYME ELECTRODE - A POTENTIAL SENSOR FOR ENVIRONMENT CONTROL [J].
DURSO, EM ;
COULET, PR .
ANALYTICA CHIMICA ACTA, 1990, 239 (01) :1-5
[8]   The phosphate sensor [J].
Engblom, SO .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (09) :981-994
[9]   Reagentless carbon paste phosphate biosensors: preliminary studies [J].
Fernandez, JJ ;
Lopez, JR ;
Correig, X ;
Katakis, I .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 47 (1-3) :13-20
[10]  
Gajovic N, 1999, ELECTROANAL, V11, P1377, DOI 10.1002/(SICI)1521-4109(199912)11:18<1377::AID-ELAN1377>3.0.CO