Phosphate biosensor based on polyelectrolyte-stabilized pyruvate oxidase

被引:55
作者
Gavalas, VG [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Dept Chem, Analyt Chem Lab, Iraklion 71409, Crete, Greece
关键词
recombinant pyruvate oxidase; phosphate; biosensor; polyelectrolyte; porous carbon electrode; serum analysis;
D O I
10.1016/S0003-2670(00)01204-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the development of a pyruvate oxidase-based phosphate biosensor is illustrated. The use of polyelectrolyte stabilized recombinant pyruvate oxidase in conjunction with a porous conductive carbon results in the development of a simple, reproducible and stable phosphate biosensor. The polyelectrolyte diethylaminoethyl-dextran or DNA was used as the enzyme stabilizer, and the resulting enzyme-polyelectrolyte complexes were physically adsorbed into the transducer, a highly porous and conductive carbon electrode, for the construction of the biosensor. The optimized biosensor exhibits high operational (67% remaining activity after 220 h) and storage (49% remaining activity after 24 weeks) stability, and very good sensor-to-sensor reproducibility. The optimized phosphate biosensor was used for the measurement of the phosphate ion activity in serum. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 30 条
[11]  
2-B
[12]   Novel pre-oxidizing cell for elimination of electroactive interferents during biosensor analysis. Application to glucose determination in real samples [J].
Gavalas, VG ;
Fouskaki, MG ;
Chaniotakis, NA .
ANALYTICAL LETTERS, 2000, 33 (12) :2391-2405
[13]   Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode [J].
Gavalas, VG ;
Chaniotakis, NA ;
Gibson, TD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1205-1211
[14]   Polyelectrolyte stabilized oxidase based biosensors: effect of diethylaminoethyl-dextran on the stabilization of glucose and lactate oxidases into porous conductive carbon [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :67-73
[15]  
GAVALAS VG, UNPUB MIKROCHIM ACTA
[16]  
GIBSON TD, 1992, ACS SYM SER, V487, P40
[17]   AMPEROMETRIC DETERMINATION OF PHOSPHATE BY USE OF A NUCLEOSIDE PHOSPHORYLASE XANTHINE-OXIDASE ENZYME SENSOR BASED ON A CLARK-TYPE HYDROGEN-PEROXIDE OR OXYGEN-ELECTRODE [J].
HAEMMERLI, SD ;
SULEIMAN, AA ;
GUILBAULT, GG .
ANALYTICAL BIOCHEMISTRY, 1990, 191 (01) :106-109
[18]   Maltose phosphorylase from Lactobacillus brevis: Purification, characterization, and application in a biosensor for ortho-phosphate [J].
Huwel, S ;
Haalck, L ;
Conrath, N ;
Spener, F .
ENZYME AND MICROBIAL TECHNOLOGY, 1997, 21 (06) :413-420
[19]  
KOPETZKI E, 1994, CLIN CHEM, V40, P688
[20]   PHOSPHATE SENSOR COMPOSED FROM IMMOBILIZED PYRUVATE OXIDASE AND AN OXYGEN-ELECTRODE [J].
KUBO, I ;
INAGAWA, M ;
SUGAWARA, T ;
ARIKAWA, Y ;
KARUBE, I .
ANALYTICAL LETTERS, 1991, 24 (10) :1711-1727