Measuring protein interactions by microchip self-interaction chromatography

被引:43
作者
García, CD
Hadley, DJ
Wilson, WW
Henry, CS [2 ]
机构
[1] Mississippi State Univ, Dept Chem, Mississippi State, MS 39762 USA
[2] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
D O I
10.1021/bp025788z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The self-interaction of proteins is of paramount importance in aggregation and crystallization phenomena. Solution conditions leading to a change in the state of aggregation of a protein, whether amorphous or crystalline, have mainly been discovered by the use of trial and error screening of large numbers of solutions. Self-interaction chromatography has the potential to provide a quantitative method for determination of protein self-interactions amenable to high-throughput screening. This paper describes the construction and characterization of a microchip separation system for low-pressure self-interaction chromatography using lysozyme as a model protein. The retention time was analyzed as a function of mobile-phase composition, amount of protein injected, flow rate, and stationary-phase modification. The capacity factors (k') as a function of crystallizing agent concentration are compared with previously published values for the osmotic second virial coefficient (B-22) obtained by static light scattering, showing the ability of the chip to accurately determine protein-protein interactions. A 500-fold reduction in protein consumption and the possibility of using conventional instrumentation and automation are some of the advantages over currently used methodologies for evaluating protein-protein interactions.
引用
收藏
页码:1006 / 1010
页数:5
相关论文
共 30 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[3]   Diamond microchips for fast chromatography of proteins [J].
Björkman, H ;
Ericson, C ;
Hjertén, S ;
Hjort, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :71-77
[4]   An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases [J].
Ceriotti, L ;
de Rooij, NF ;
Verpoorte, E .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :639-647
[5]   Is lysozyme really the ideal model protein? [J].
Chayen, NE ;
Saridakis, E .
JOURNAL OF CRYSTAL GROWTH, 2001, 232 (1-4) :262-264
[6]   Rapid prototyping of microfluidic switches in poly(dimethyl siloxane) and their actuation by electro-osmotic flow [J].
Duffy, DC ;
Schueller, OJA ;
Brittain, ST ;
Whitesides, GM .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1999, 9 (03) :211-217
[7]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[8]  
GARCIA CD, 2003, IN PRESS BIOTECHNOL
[9]   PREDICTING PROTEIN CRYSTALLIZATION FROM A DILUTE-SOLUTION PROPERTY [J].
GEORGE, A ;
WILSON, WW .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1994, 50 :361-365
[10]   Correlation of second virial coefficients and solubilities useful in protein crystal growth [J].
Guo, B ;
Kao, S ;
McDonald, H ;
Asanov, A ;
Combs, LL ;
Wilson, WW .
JOURNAL OF CRYSTAL GROWTH, 1999, 196 (2-4) :424-433