The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting

被引:64
作者
Moore, Ginny [1 ]
Smyth, Debbie
Singleton, Julie [2 ]
Wilson, Peter
机构
[1] Univ Coll London Hosp NHS Fdn Trust, Environm Lab, Windeyer Inst Med Sci, Dept Microbiol, 46 Cleveland St, London W1T 4JF, England
[2] Royal Free Hampstead NHS Trust, Dept Intens Care, London, England
关键词
Adenosine triphosphate bioluminescence; ATP bioluminescence; intensive care unit; cleaning; BACTERIA; SURFACES; CLOTHS;
D O I
10.1016/j.ajic.2010.02.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: A total environmental cleaning system based on microfiber technology was implemented within 2 intensive care units (ICUs). The efficacy of this modified cleaning program was assessed using adenosine triphosphate (ATP) bioluminescence. Methods: A team of trained hygiene technicians cleaned all near-patient furniture and equipment twice a day using ultramicrofiber cloths. Every week for 40 weeks, 10 surfaces within a randomly selected bed area were sampled using the 3M Clean-Trace Clinical Hygiene Monitoring System (3M Health Care Ltd, Loughborough, United Kingdom). The ability of the modified cleaning program to reduce surface contamination to "acceptable" levels was measured against previously proposed benchmark ATP values. Results: In comparison with normal cleaning procedures routinely carried out by the nurses, the modified cleaning program significantly reduced (P < .001) the ATP readings obtained from surfaces within the near-patient environment. In both ICUs, 95% of surfaces sampled after modified cleaning had relative light unit values of <500 and were deemed "clean." Almost 90% of the surfaces could also be "passed" using the more stringent benchmark value of 250 relative light units. However, regardless of benchmark value used, the majority of surfaces sampled could also be considered adequately clean prior to them being cleaned by the hygiene technicians. Conclusion: The use of ATP bioluminescence has been proposed as a means to improve the management of hospital cleaning. Use of benchmark values can help continually monitor the efficacy of existing cleaning programs. However, when evaluating novel or new cleaning practices, baseline cleanliness (ie, the level of cleanliness routinely achieved using normal cleaning procedures) must also be taken into consideration, or the efficacy of modified cleaning will be overestimated.
引用
收藏
页码:617 / 622
页数:6
相关论文
共 20 条
  • [1] Floor cleaning: effect on bacteria and organic materials in hospital rooms
    Andersen, B. M.
    Rasch, M.
    Kvist, J.
    Tollefsen, T.
    Lukkassen, R.
    Sandvik, L.
    Welo, A.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2009, 71 (01) : 57 - 65
  • [2] Spread of bacteria on surfaces when cleaning with microfibre cloths
    Bergen, L. K.
    Meyer, M.
    Hog, M.
    Rubenhagen, B.
    Andersen, L. P.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2009, 71 (02) : 132 - 137
  • [3] Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay
    Boyce, John M.
    Havill, Nancy L.
    Dumigan, Diane G.
    Golebiewski, Michael
    Balogun, Ola
    Rizvani, Ramo
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (07) : 678 - 684
  • [4] Monitoring the effectiveness of cleaning in four British hospitals
    Cooper, Rose A.
    Griffith, Chris J.
    Malik, Rifhat E.
    Obee, Peter
    Looker, Nick
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2007, 35 (05) : 338 - 341
  • [5] *DEP HLTH NHS PURC, HEALTHC ASS INF HCAI
  • [6] Three novel highly charged copper-based biocides: safety and efficacy against healthcare-associated organisms
    Gant, Vanya A.
    Wren, Michael W. D.
    Rollins, Michael S. M.
    Jeanes, Annette
    Hickok, Stephen S.
    Haj, Tony J.
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2007, 60 (02) : 294 - 299
  • [7] The effectiveness of existing and modified cleaning regimens in a Welsh hospital
    Griffith, C. J.
    Obee, P.
    Cooper, R. A.
    Burton, N. F.
    Lewis, M.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 66 (04) : 352 - 359
  • [8] An evaluation of hospital cleaning regimes and standards
    Griffith, CJ
    Cooper, RA
    Gilmore, J
    Davies, C
    Lewis, M
    [J]. JOURNAL OF HOSPITAL INFECTION, 2000, 45 (01) : 19 - 28
  • [9] A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces
    Lewis, T.
    Griffith, C.
    Gallo, M.
    Weinbren, M.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2008, 69 (02) : 156 - 163
  • [10] A laboratory evaluation of the decontamination properties of microfibre cloths
    Moore, G.
    Griffith, C.