Comparison of tomosynthesis methods used with digital mammography

被引:99
作者
Suryanarayanan, S
Karellas, A
Vedantham, S
Glick, SJ
D'Orsi, CJ
Baker, SP
Webber, RL
机构
[1] Univ Massachusetts, Sch Med, Mem Med Ctr, Dept Radiol, Worcester, MA 01605 USA
[2] Wake Forest Univ, Bowman Gray Sch Med, Winston Salem, NC 27157 USA
关键词
breast neoplasms; diagnosis; breast radiography; technology; images; digitization; processing;
D O I
10.1016/S1076-6332(00)80061-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors performed this study to investigate the potential applicability of tomosynthesis to digital mammography, Four methods of tomosynthesis-tuned aperture computed tomography (TACT)-backprojection, TACT-iterative restoration, iterative reconstruction with expectation maximization, and Bayesian smoothing-were compared to planar mammography and analyzed in terms of their contrast-detail characteristics. Specific comparisons between the tomosynthesis methods were not attempted in this study. Materials and Methods. A full-field, amorphous, silicon-based, flat-panel digital mammographic system was used to obtain planar and tomosynthesis projection images. A composite tomosynthesis phantom with a centrally located contrast-detail insert was used as the object of interest. The total exposure for multiple views with tomosynthesis was always equal to or less than that for the planar technique. Algorithms were used to reconstruct the object from the acquired projections. Results. Threshold contrast characteristics with all tomosynthesis reconstruction methods were significantly better than those with planar mammography, even when planar mammography was performed at more than twice the exposure level. Reduction of out-of-plane structural components was observed in all the tomosynthesis methods analyzed. Conclusion. The contrast-detail trends of all the tomosynthesis methods analyzed in this study were better than those of planar mammography. Further optimization of the algorithms could lead to better image reconstruction, which would improve visualization of valuable diagnostic information.
引用
收藏
页码:1085 / 1097
页数:13
相关论文
共 42 条
[1]   Bayesian image reconstruction for emission tomography based on median root prior [J].
Alenius, S ;
Ruotsalainen, U .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) :258-265
[2]  
Armitage P, 1987, Statistical methods in medical research, V2nd
[3]   DIGITIZED LONGITUDINAL TOMOGRAPHY [J].
BAILY, NA ;
KAMPP, TD .
INVESTIGATIVE RADIOLOGY, 1981, 16 (02) :126-132
[4]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[5]   X-ray characterization of breast phantom materials [J].
Byng, JW ;
Mainprize, JG ;
Yaffe, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1367-1377
[6]   SELF-MASKING SUBTRACTION TOMOSYNTHESIS [J].
CHAKRABORTY, DP ;
YESTER, MV ;
BARNES, GT ;
LAKSHMINARAYANAN, AV .
RADIOLOGY, 1984, 150 (01) :225-229
[7]   ANALYSIS OF VARIATIONS IN CONTRAST-DETAIL EXPERIMENTS [J].
COHEN, G ;
MCDANIEL, DL ;
WAGNER, LK .
MEDICAL PHYSICS, 1984, 11 (04) :469-473
[8]   COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1994, 21 (05) :691-695
[9]  
des Plantes BGZ, 1932, ACTA RADIOL, V13, P182
[10]   3 DIMENSIONAL ROENTGENOGRAPHY [J].
GARRISON, JB ;
GRANT, DG ;
GUIER, WH ;
JOHNS, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1969, 105 (04) :903-&