Cryogenic high-resolution X-ray spectrometers for SR-XRF and microanalysis

被引:11
作者
Frank, M
Mears, CA
Labov, SE
Hiller, LJ
le Grand, JB
Lindeman, MA
Netel, H
Chow, D
Barfknecht, AT
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[2] Conductus Inc, Sunnyvale, CA 94086 USA
关键词
cryogenic detectors; low-temperature detectors; microcalorimeters; X-ray fluorescence; X-ray spectroscopy;
D O I
10.1107/S0909049597014465
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Experimental results are presented obtained with a cryogenically cooled high-resolution X-ray spectrometer based on a 141 x 141 mu m Nb-Al-Al2O3-Al-Nb superconducting tunnel junction (STJ) detector in an SR-XRF demonstration experiment. STJ detectors can operate at count rates approaching those of semiconductor detectors while still providing a significantly better energy resolution for soft X-rays. By measuring fluorescence X-rays from samples containing transition metals and low-Z elements, an FWHM energy resolution of 6-15 eV for X-rays in the energy range 180-1100 eV has been obtained. The results show that, in the near future, STJ detectors may prove very useful in XRF and microanalysis applications.
引用
收藏
页码:515 / 517
页数:3
相关论文
共 15 条
[1]   A SIMPLE AND ROBUST NIOBIUM JOSEPHSON JUNCTION INTEGRATED-CIRCUIT PROCESS [J].
BARFKNECHT, AT ;
RUBY, RC ;
KO, H .
IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) :3125-3128
[2]   Superconducting particle detectors [J].
Booth, NE ;
Goldie, DJ .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (07) :493-516
[3]   QUASI-PARTICLE TRAPPING AND THE QUASI-PARTICLE MULTIPLIER [J].
BOOTH, NE .
APPLIED PHYSICS LETTERS, 1987, 50 (05) :293-295
[4]   SOFT-X-RAY SPECTROSCOPY OF METALLOPROTEINS USING FLUORESCENCE DETECTION [J].
CRAMER, SP ;
CHEN, J ;
GEORGE, SJ ;
VANELP, J ;
MOORE, J ;
TENSCH, O ;
COLARESI, J ;
YOCUM, M ;
MULLINS, OC ;
CHEN, CT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 319 (1-3) :285-289
[5]  
FRANK M, 1998, IN PRESS REV SCI INS, V69
[6]   STATISTICAL NOISE DUE TO TUNNELING IN SUPERCONDUCTING TUNNEL JUNCTION DETECTORS [J].
GOLDIE, DJ ;
BRINK, PL ;
PATEL, C ;
BOOTH, NE ;
SALMON, GL .
APPLIED PHYSICS LETTERS, 1994, 64 (23) :3169-3171
[7]  
HILLER LJ, 1995, P SOC PHOTO-OPT INS, V2518, P249, DOI 10.1117/12.218381
[8]   ENERGY-RESOLVING SUPERCONDUCTING X-RAY-DETECTORS WITH CHARGE AMPLIFICATION DUE TO MULTIPLE QUASI-PARTICLE TUNNELING [J].
MEARS, CA ;
LABOV, SE ;
BARFKNECHT, AT .
APPLIED PHYSICS LETTERS, 1993, 63 (21) :2961-2963
[9]   Analysis of pulse shape from a high-resolution superconducting tunnel junction X-ray spectrometer [J].
Mears, CA ;
Labov, SE ;
Frank, M ;
Lindeman, MA ;
Hiller, LJ ;
Netel, H ;
Barfknecht, AT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01) :53-56
[10]   HIGH-RESOLUTION SUPERCONDUCTING X-RAY SPECTROMETERS WITH ALUMINUM TRAPPING LAYERS OF DIFFERENT THICKNESSES [J].
MEARS, CA ;
LABOV, SE ;
HILLER, LH ;
FRANK, M ;
NETEL, H ;
AZGUI, F ;
BARFKNECHT, AT .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) :3069-3072