Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T

被引:67
作者
Wang, Z
Wang, JJ
Connick, TJ
Wetmore, GS
Detre, JA
机构
[1] Univ Penn, Sch Med, Ctr Funct Neuroimaging, Dept Neurol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
ASL perfusion imaging; parallel imaging; GRAPPA; CBF; SNR;
D O I
10.1002/mrm.20574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to assess the feasibility and efficacy of using an array coil and parallel imaging in continuous arterial spin labeling (CASL) perfusion MRI. An 8-channel receive-only array head coil was used in conjunction with a surrounding detunable volume transmit coil. The signal to noise ratio (SNR), temporal stability, cerebral blood flow (CBF), and perfusion image coverage were measured from steady state CASL scans using: a standard volume coil, array coil, and array coil with 2- and 3-fold accelerated parallel imaging. Compared to the standard volume coil, the array coil provided 3 times the average SNR increase and higher temporal stability for the perfusion weighted images, even with threefold acceleration. Although perfusion images of the array coil were affected by the inhomogeneous coil sensitivities, this effect was invisible in the quantitative CBF images, which showed highly reproducible perfusion values compared to the standard volume coil. The unfolding distortions of parallel imaging were suppressed in the perfusion images by pairwise subtraction, though they sharply degraded the raw EPI images. Moreover, parallel imaging provided the potential of acquiring more slices due to the shortened acquisition time and improved coverage in brain regions with high static field inhomogeneity. Such results highlight the potential utility of array coils and parallel imaging in ASL perfusion MRI.
引用
收藏
页码:732 / 737
页数:6
相关论文
共 20 条
  • [11] Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)
    Preibisch, C
    Pilatus, U
    Bunke, R
    Hoogenraad, F
    Zanella, F
    Lanfermann, H
    [J]. NEUROIMAGE, 2003, 19 (02) : 412 - 421
  • [12] Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
  • [13] 2-S
  • [14] THE NMR PHASED-ARRAY
    ROEMER, PB
    EDELSTEIN, WA
    HAYES, CE
    SOUZA, SP
    MUELLER, OM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 192 - 225
  • [15] Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
    Talagala, SL
    Ye, FQ
    Ledden, PJ
    Chesnick, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 131 - 140
  • [16] Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla
    Wang, JJ
    Alsop, DC
    Li, L
    Listerud, J
    Gonzalez-At, JB
    Schnall, MD
    Detre, JA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 242 - 254
  • [17] WANG JJ, 2005, IN PRESS RADIOLOGY
  • [18] Wong EC, 2000, MED RAD DIA IMG, P63
  • [19] Zaharchuk G, 1999, MAGNET RESON MED, V41, P1093, DOI 10.1002/(SICI)1522-2594(199906)41:6<1093::AID-MRM4>3.0.CO
  • [20] 2-0