Evaluation of a new leg length measurement algorithm in hip arthroplasty

被引:46
作者
Murphy, Stephen B. [1 ]
Ecker, Timo M. [1 ]
机构
[1] New England Baptist Hosp, Ctr Comp Assisted & Reconstruct Surg, Boston, MA USA
关键词
D O I
10.1097/BLO.0b013e318126c08f
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Leg length inequality after hip arthroplasty is a major source of patient dissatisfaction and dysfunction. Despite numerous reported methods to intraoperatively determine leg length change, it remains a challenge. We developed a reliable and reproducible method to measure leg length change using surgical navigation. The method measures the change in position of the femur relative to the pelvis and the pelvic coordinate system without the need to establish a femoral coordinate system. We replaced 112 hips in 107 patients using the new leg length measurement algorithm. Leg length change measured at surgery was compared with leg length change as measured on magnification-corrected pre- and postoperative radiographs. Compared with radiographically measured leg length change, the leg length changes measured intraoperatively had a mean difference of -0.5 +/- 1.77 mm (range, -5-3.9 mm). We found no difference between radiographic data and navigation data. Leg length change measured using surgical navigation, measuring the change in position of the femur relative to the pelvic coordinate system, without establishing a femoral coordinate system is easy and reliable. Level of Evidence: Level IV, therapeutic study.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 25 条
[1]
Computed tomography-based navigation for hip, knee, and spine surgery [J].
Amiot, LP ;
Poulin, F .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (421) :77-86
[2]
ANDA S, 1990, ACTA RADIOL, V31, P389
[3]
Bose WJ, 2000, ORTHOPEDICS, V23, P433
[4]
Cuckler JM, 2005, ORTHOPEDICS, V28, P951
[5]
EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING [J].
GOERGEN, TG ;
RESNICK, D .
BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) :259-260
[6]
Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults [J].
Gurney, B ;
Mermier, C ;
Robergs, R ;
Gibson, A ;
Rivero, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (06) :907-915
[7]
Computer assisted measurement of cup placement in total hip replacement [J].
Jaramaz, B ;
DiGioia, AM ;
Blackwell, M ;
Nikou, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) :70-81
[8]
The importance of leg length discrepancy after total hip arthroplasty [J].
Konyves, A ;
Bannister, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :155-157
[9]
Langlotz F, 2006, ORTHOPADE, V35, P1032, DOI 10.1007/s00132-006-0993-z
[10]
A simple method to minimize limb-length discrepancy after hip arthroplasty [J].
Matsuda, Kenta ;
Nakamura, Shigeru ;
Matsushita, Takashi .