This paper will review the recent advances and future developments in the field of coincidence imaging of positron emitters with a conventional Anger-type gamma camera. FDG imaging has shown high clinical importance in cardiology, neurology and especially oncology. Since access to full ring PET is mainly limited to university hospitals, there have been new developments allowing PET imaging on the standard Anger gamma camera. First the principles of coincidence imaging on a gamma camera will be reviewed. We will discuss the limitations of this technique, and the techniques used to partly overcome these limitations. The different configurations of the gamma camera operating in coincidence mode are pointed out. Different corrections for image degrading effects and reconstruction methods are evaluated in the final part. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 30 条
[11]   PET in oncology: Will it replace the other modalities? [J].
Hoh, CK ;
Schiepers, C ;
Seltzer, MA ;
Gambhir, SS ;
Silverman, DHS ;
Czernin, J ;
Maddahi, J ;
Phelps, ME .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (02) :94-106
[12]   PET imaging using gamma camera systems: A review [J].
Jarritt, PH ;
Acton, PD .
NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (09) :758-766
[13]   Attenuation effects in gamma-camera coincidence imaging [J].
Laymon, CM ;
Turkington, TG ;
Coleman, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3115-3121
[14]  
LEVKOVITZ R, 1999, INT M FULL 3D IM REC, P216
[15]   PET imaging using dual-headed gamma cameras: An update [J].
Lewellen, TK ;
Miyaoka, RS ;
Swan, WL .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (01) :5-12
[16]   3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR PET BY MULTISLICE REBINNING AND AXIAL IMAGE FILTERING [J].
LEWITT, RM ;
MUEHLLEHNER, G ;
KARP, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :321-339
[17]   Advances in nuclear medicine instrumentation: considerations in the design and selection of an imaging system [J].
Links, JM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (10) :1453-1466
[18]   Detection of malignancies with SPECT versus PET, with 2-[fluorine-18]fluoro-2-deoxy-D-glucose [J].
Martin, WH ;
Delbeke, D ;
Patton, JA ;
Sandler, MP .
RADIOLOGY, 1996, 198 (01) :225-231
[19]  
Patton JA, 1999, J NUCL MED, V40, P432
[20]   BAR-DETECTOR WITH EXTENDED FIELD-OF-VIEW FOR A MODULAR SPECT SYSTEM [J].
PAWLOWSKI, J ;
KARI, B ;
WEI, C ;
LIU, YN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1130-1133