Capillary isoelectric focusing with whole column detection and a membrane sample preparation system

被引:37
作者
Wu, JQ
Tragas, C
Watson, A
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Convergent Biosci Ltd, Toronto, ON M8Z 2L8, Canada
关键词
capillary isoelectric focusing; whole column detector; imaging detector; on-line desalting device; protein analysis;
D O I
10.1016/S0003-2670(98)00489-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Progress of the research on capillary isoelectric focusing (clEF)-whole column detection is reviewed. Three kinds of whole column detectors have been developed for cIEF: universal refractive index gradient imaging detector, laser-induced fluorescence (LIF) imaging detector, and optical absorption detector. Principle, applicability and detection limit of these detectors are discussed. A capillary column cartridge specially designed for cIEF with whole column detection is introduced. The column cartridge uses microdialysis hollow fiber membranes to isolate the sample solution from the electrolytes. Sample can be directly injected into the column without disturbing the electrolytes using a syringe pump or a liquid chromatography autosampler. The cartridge incorporates an on-line desalting, carrier ampholytes mixing device which also uses a microdialysis hollow fiber membrane. The on-line device adapts cIEF to a variety of analytical matrices. Examples of application of different whole column detectors to cIEF are shown in the review. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 20 条
[11]   WHOLE COLUMN ABSORBENCY DETECTION IN CAPILLARY ISOELECTRIC-FOCUSING [J].
WANG, TS ;
HARTWICK, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (15) :1745-1747
[12]   DUAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITH REFRACTIVE-INDEX GRADIENT AND ABSORPTION IMAGING DETECTORS [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :867-873
[13]   UNIVERSAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITHOUT MOBILIZATION USING A CONCENTRATION GRADIENT IMAGING-SYSTEM [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :224-227
[14]   ABSORPTION-SPECTRA AND MULTICAPILLARY IMAGING DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING USING A CHARGE-COUPLED-DEVICE CAMERA [J].
WU, JQ ;
PAWLISZYN, J .
ANALYST, 1995, 120 (05) :1567-1571
[15]   IN-VITRO OBSERVATION OF INTERACTIONS OF IRON AND TRANSFERRIN BY CAPILLARY ISOELECTRIC-FOCUSING WITH A CONCENTRATION GRADIENT IMAGING DETECTION SYSTEM [J].
WU, JQ ;
PAWLISZYN, J .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :295-299
[16]   CAPILLARY ISOELECTRIC-FOCUSING WITH A UNIVERSAL CONCENTRATION GRADIENT IMAGING-SYSTEM USING A CHARGE-COUPLED PHOTODIODE ARRAY [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2934-2941
[17]   A CAPILLARY CARTRIDGE WITH AN ONLINE DESALTING DEVICE THAT ALLOW FAST SAMPLING FOR CAPILLARY ISOELECTRIC-FOCUSING [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2010-2014
[18]   Optimizing separation conditions for proteins and peptides using imaged capillary isoelectric focusing [J].
Wu, JQ ;
Li, SC ;
Watson, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :163-171
[19]   FLUORESCENCE IMAGING DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING [J].
WU, XZ ;
WU, JQ ;
PAWLISZYN, J .
ELECTROPHORESIS, 1995, 16 (08) :1474-1478
[20]   A micromethod for concentration and desalting utilizing a hollow fiber, with special reference to capillary electrophoresis [J].
Zhang, R ;
Hjerten, S .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1585-1592