Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: A study in 10 cadaver femora

被引:23
作者
Kort, N. P.
van Raay, J. J. A. M.
Thomassen, B. J. W.
机构
[1] Martini Hosp, Dept Orthoped, NL-9700 RM Groningen, Netherlands
[2] Maasland Hosp, Dept Orthoped, NL-6130 MB Sittard, Netherlands
关键词
unicompartmental knee; alignment; femoral component; intramedullary rod; extramedullary rod;
D O I
10.1016/j.knee.2007.04.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Use of an intramedullary rod is advised for the alignment of the femoral component of an Oxford phase-III prosthesis. There are users moving toward extramedullary alignment, which is merely an indicator of frustration with accuracy of intramedullary alignment. The results of our study with 10 cadaver femora demonstrate that use of a short and long intramedullary femoral rod may result in excessive flexion alignment error of the femoral component. Understanding of the extramedullary alignment possibility and experience with the visual alignment of the femoral drill guide is essential toward minimizing potential errors in the alignment of the femoral component. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:280 / 283
页数:4
相关论文
共 7 条
[1]
[Anonymous], DOSIMETRY IONIZING R
[2]
Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty [J].
Ma, B ;
Long, W ;
Rudan, JF ;
Ellis, RE .
JOURNAL OF ARTHROPLASTY, 2006, 21 (02) :271-278
[3]
The Oxford medial unicompartmental arthroplasty - A ten-year survival study [J].
Murray, DW ;
Goodfellow, JW ;
O'Connor, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (06) :983-989
[4]
Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty [J].
Novotny, J ;
Gonzalez, MH ;
Amirouche, FML ;
Li, YC .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :641-647
[5]
Rapid recovery after oxford unicompartmental arthroplasty through a short incision [J].
Price, AJ ;
Webb, J ;
Topf, H ;
Dodd, CAF ;
Goodfellow, JW ;
Murray, DW .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :970-976
[6]
Wear of congruent meniscal bearings in unicompartmental knee arthroplasty - A retrieval study of 16 specimens [J].
Psychoyios, V ;
Crawford, RW ;
O'Connor, JJ ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (06) :976-982
[7]
Accuracy of implantation of components in the Oxford knee using the minimally invasive approach [J].
Shakespeare, D ;
Ledger, M ;
Kinzel, V .
KNEE, 2005, 12 (06) :405-409