Application of glow discharge Fourier-transform ion cyclotron resonance mass spectrometry to isotope ratio measurements

被引:6
作者
Barshick, CM [1 ]
Goodner, KL
Watson, CH
Eyler, JR
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
[2] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
GDMS; isotope ratio measurements; FTICR; isotopic bias; high resolution;
D O I
10.1016/S1387-3806(98)14087-3
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The combination of a glow discharge ionization source with a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer provides several advantages for elemental analysis; among these is an isotope ratio measured at the highest possible mass resolving power. In this report, lead ratios (Pb-206/Pb-208, Pb-207/Pb-208, and Pb-207/Pb-206) in a sample composed of 10% lead oxide, 10% mercuric oxide, and 80% silver powder (w/w) were observed to be precise to better than +/-3% relative standard deviation (RSD at 1 sigma) in a commercial FTICR instrument that used a conventional elongated cell. Upon incorporation of a cell whose excitation voltages approximated those in an ideal cell of infinite length, the precision improved to better than +0.4% RSD. The isotopic bias between measured and known values was also evaluated. Using a cathode composed of 5% National Institute of Standards and Technology (NIST) SRM 987 SrCO3 in silver powder, biases that averaged less than 2.5% were detected using the cell of improved design. These results compared favorably with those obtained using a commercial magnetic sector glow discharge mass spectrometer, although it is still unclear how glow discharge mass spectrometry biases vary in general. (Int J Mass Spectrom 178 (1998) 73-79) (C) 1998 Elsevier Science B.V.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 25 条
[1]  
BAMBERG M, 1987, 35TH P ASMS C MASS S, P1116
[2]   ISOTOPE-DILUTION GLOW-DISCHARGE MASS-SPECTROMETRY AS APPLIED TO THE ANALYSIS OF LEAD IN WASTE OIL SAMPLES [J].
BARSHICK, CM ;
SMITH, DH ;
WADE, JW ;
BAYNE, CK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (02) :83-87
[3]   A GLOW-DISCHARGE ION-SOURCE WITH FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRIC DETECTION [J].
BARSHICK, CM ;
EYLER, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (02) :122-127
[4]   AN IMPROVED ION GUIDE FOR EXTERNAL ION INJECTION IN GLOW-DISCHARGE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BARSHICK, CM ;
EYLER, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (05) :387-392
[5]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[6]  
DATE AR, 1991, SPECTROCHIM ACTA REV, V14, P3
[7]   ISOTOPIC MEASUREMENTS OF PALLADIUM METAL CONTAINING PROTIUM AND DEUTERIUM BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DONOHUE, DL ;
PETEK, M .
ANALYTICAL CHEMISTRY, 1991, 63 (07) :740-744
[8]   ISOTOPIC ANALYSIS OF RARE-EARTH ELEMENTS BY TOTAL VAPORIZATION OF SAMPLES IN THERMAL IONIZATION MASS-SPECTROMETRY [J].
DUBOIS, JC ;
RETALI, G ;
CESARIO, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 120 (03) :163-177
[9]   DIRECT MEASUREMENT OF URANIUM ISOTOPIC-RATIOS IN SOILS BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
BARSHICK, CM ;
BOSTICK, DA ;
SMITH, DH .
APPLIED SPECTROSCOPY, 1993, 47 (02) :243-245
[10]   RESOLUTION ENHANCEMENT IN FT NMR THROUGH USE OF A DOUBLE EXPONENTIAL FUNCTION [J].
FERRIGE, AG ;
LINDON, JC .