Reference spectrum extraction and fixed-pattern noise removal in optical coherence tomography

被引:54
作者
Moon, Sucbei [1 ]
Lee, Sang-Won [1 ]
Chen, Zhongping [1 ,2 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
基金
美国国家卫生研究院;
关键词
RATIO;
D O I
10.1364/OE.18.024395
中图分类号
O43 [光学];
学科分类号
070207 [光学];
摘要
We present a new signal processing method that extracts the reference spectrum information from an acquired optical coherence tomography (OCT) image without a separate calibration step of reference spectrum measurement. The reference spectrum is used to remove the fixed-pattern noise that is a characteristic artifact of Fourier-domain OCT schemes. It was found that the conventional approach based on an averaged spectrum, or mean spectrum, is prone to be influenced by the high-amplitude data points whose statistical distribution is hardly randomized. Thus, the conventional mean-spectrum subtraction method cannot completely eliminate the artifact but may leave residual horizontal lines in the final image. This problem was avoided by utilizing an advanced statistical analysis tool of the median A-line. The reference A-line was obtained by taking a complex median of each horizontal-line data. As an optional method of high-speed calculation, we also propose a minimum-variance mean A-line that can be calculated from an image by a collection of mean A-line values taken from a horizontal segment whose complex variance of the data points is the minimum. By comparing the images processed by those methods, it was found that our new processing schemes of the median-line subtraction and the minimum-variance mean-line subtraction successfully suppressed the fixed-pattern noise. The inverse Fourier transform of the obtained reference A-line well matched the reference spectrum obtained by a physical measurement as well. (C) 2010 Optical Society of America
引用
收藏
页码:24395 / 24404
页数:10
相关论文
共 9 条
[1]
de Boer JF, 2008, BIOL MED PHYS BIOMED, P147
[2]
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[3]
Langley R., 1971, PRACTICAL STAT
[4]
Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[5]
Leitgeb RA, 2008, BIOL MED PHYS BIOMED, P176
[6]
In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve [J].
Nassif, NA ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Yun, SH ;
Bouma, BE ;
Tearney, GJ ;
Chen, TC ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (03) :367-376
[7]
Limitation of the achievable signal-to-noise ratio in optical coherence tomography due to mismatch of the balanced receiver [J].
Rosa, CC ;
Podoleanu, AG .
APPLIED OPTICS, 2004, 43 (25) :4802-4815
[8]
Spectral shaping for non-Gaussian source spectra in optical coherence tomography [J].
Tripathi, R ;
Nassif, N ;
Nelson, JS ;
Park, BH ;
de Boer, JF .
OPTICS LETTERS, 2002, 27 (06) :406-408
[9]
High-speed optical frequency-domain imaging [J].
Yun, SH ;
Tearney, GJ ;
de Boer, JF ;
Iftimia, N ;
Bouma, BE .
OPTICS EXPRESS, 2003, 11 (22) :2953-2963