Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 tesla

被引:74
作者
Jesmanowicz, A [1 ]
Bandettini, PA [1 ]
Hyde, JS [1 ]
机构
[1] Med Coll Wisconsin, Biophys Res Inst, Milwaukee, WI 53226 USA
关键词
echo-planar imaging; functional magnetic resonance imaging; neuroimaging; MRI pulse sequence;
D O I
10.1002/mrm.1910400517
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T-2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution, In addition, the long readout time for high-resolution full k-space acquisition gives rise to severe susceptibility effects. These problems are substantially reduced by acquiring only half of k-space and filling the empty side by Hermitian conjugate formation. Details of the pulse sequence and image reconstruction are presented, The point-spread function is 3(1/2) times narrower for half than full k-space acquisition, Experiments as well as theoretical considerations were carried out in a context of fMRI using a whole-brain local gradient and an RF coil at 3 Tesla, Using a bandwidth of +/-83 kHz, well-resolved single-shot images of the human brain, as well as good quality fMRI data sets were obtained with a matrix of 192 x 192 over 16 x 16 cm(2) FOV using half k-space techniques, The combination of high spatial resolution using the methods presented in this article and the high temporal resolution of EPI opens opportunities for research into fMRI contrast mechanisms. Increase of percent signal change as the resolution increases is attributed to reduction of partial volume effects of activated voxels, Histograms of fMRI pixel responses are progressively weighted to higher percent signal changes as the resolution increases. The conclusion has been reached that half k-space GR-EPI is generally superior to full k-space GR-EPI and should be used even for low-resolution (64 x 64) EPI.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 38 条
[1]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[2]  
BANDETTINI P, 1995, THESIS MED COLL WISC
[3]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[4]  
Bandettini PA, 1994, P SMR 2 ANN M SAN FR, P434
[5]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[6]  
BISWAL B, 1997, P ISMRM 5 SCI M VANC, P1629
[7]   INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
THOMPSON, RM ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :67-72
[8]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[9]   ULTRA-FAST IMAGING [J].
COHEN, MS ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :1-37
[10]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139