Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods

被引:124
作者
Beltran, Chris. [1 ]
Herman, Michael G. [1 ]
Davis, Brian J. [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Radiat Oncol, Rochester, MN USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 70卷 / 01期
关键词
prostate cancer; intrafraction motion; organ motion; electronic portal imaging; target localization;
D O I
10.1016/j.ijrobp.2007.08.040
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization pro col using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the four daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0,3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction. (C) 2008 Elsevier Inc.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 41 条
[11]  
Herman M G, 2000, J Appl Clin Med Phys, V1, P38, DOI 10.1120/1.308249
[12]   Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device [J].
Herman, MG ;
Pisansky, TM ;
Kruse, JJ ;
Prisciandaro, JI ;
Davis, BJ ;
King, BF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (04) :1131-1140
[13]  
International Commission in Radiation Units and Measurements, 1999, 62 ICRU
[14]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[15]   Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123
[16]   Electronic and film portal images: A comparison of landmark visibility and review accuracy [J].
Kruse, JJ ;
Herman, MG ;
Hagness, CR ;
Davis, BJ ;
Garces, YI ;
Haddock, MG ;
Olivier, KR ;
Stafford, SL ;
Pisansky, TM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02) :584-591
[17]   Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability [J].
Kupelian, PA ;
Willoughby, TR ;
Meeks, SL ;
Forbes, A ;
Wagner, T ;
Maach, M ;
Langen, KM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1291-1296
[18]   Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer [J].
Kupelian, Patrick A. ;
Langen, Katja M. ;
Zeidan, Omar A. ;
Meeks, Sanford L. ;
Willoughby, Twyla R. ;
Wagner, Thomas H. ;
Jeswani, Sam ;
Ruchala, Kenneth J. ;
Haimerl, Jason ;
Olivera, Gustavo H. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03) :876-882
[19]   A study of the effect of setup errors and organ motion on prostate cancer treatment with IMRT [J].
Landoni, Valeria ;
Saracino, Bianca ;
Marzi, Siniona ;
Gallucci, Michaele ;
Petrongari, Maria G. ;
Chianese, Enrico ;
Benassi, Michaela ;
Iaccarino, Giuseppe ;
Soriani, Antonella ;
Arcangeli, Giorgio .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :587-594
[20]   Evaluation of ultrasound-based prostate localization for image-guided radiotherapy [J].
Langen, KM ;
Pouliot, J ;
Anezinos, C ;
Aubin, M ;
Gottschalk, AR ;
Hsu, IC ;
Lowther, D ;
Liu, YM ;
Shinohara, K ;
Verhey, LJ ;
Weinberg, V ;
Roach, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :635-644