Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device

被引:83
作者
Herman, MG
Pisansky, TM
Kruse, JJ
Prisciandaro, JI
Davis, BJ
King, BF
机构
[1] Mayo Clin & Mayo Fdn, Div Radiat Oncol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 04期
关键词
electronic portal imaging; localization; organ motion; prostate cancer; setup variation;
D O I
10.1016/S0360-3016(03)00766-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a real-time electronic portal imaging device (EPID) procedure to identify intraprostatic gold markers and correct daily variations in target position during external beam radiotherapy for prostate cancer. Methods and Materials: Pretherapy electronic portal images (EPIs) were acquired with a small portion of the therapeutic 18-MV dose from an orthogonal pair of treatment fields. The position of the intraprostatic gold markers on the EPIs was aligned with that on the simulation digitally reconstructed radiographs. If the initial three-dimensional target displacement (3DI) exceeded 5 mm or rotations exceeded 3degrees, the beam was realigned before the remainder of the dose was delivered. Field-only EPIs were then acquired for all fields and offline analysis was performed to determine the final 3D target placement (3DF). Results: Twenty patients completed protocol-specified treatment, and all markers were identified on 99.6% of the pretherapy EPIs. Overall, 53% of treatment fractions were realigned. The mean 3DI was 5.6 mm in all patients (range 3.7-9.3), and the mean 3DF was 2.8 mm (range 1.6-4.0), which was statistically significant (p < 0.001). Rotational corrections were made on 15% of treatments. Mean treatment duration was 1.4 min greater for protocol patients than for similar patients in whom localization was not performed. Conclusions: Frequent field misalignment occurs when external fiducial marks are used for patient alignment. Misalignments can be readily and rapidly identified and corrected with an EPID-based online correction procedure that integrates commercially available equipment and software. (C) 2003 Elsevier Inc.
引用
收藏
页码:1131 / 1140
页数:10
相关论文
共 33 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]   ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[5]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[6]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[7]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[8]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[9]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[10]   Target position variability throughout prostate radiotherapy [J].
Dawson, LA ;
Mah, K ;
Franssen, E ;
Morton, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (05) :1155-1161