Assessment of synthetic peptides for hepatitis A diagnosis using biosensor technology

被引:42
作者
Gómara, MJ
Ercilla, G
Alsina, MA
Haro, I
机构
[1] CSIC, IIQAB, Dept Quim Peptids & Prot, ES-08034 Barcelona, Spain
[2] Hosp Clin Barcelona, IDIBAPS, Serv Immunol, Barcelona, Spain
[3] Univ Barcelona, Fac Farm, Dept Fisicoquim, E-08028 Barcelona, Spain
关键词
hepatitis A; diagnosis; surface plasmon resonance; BIACORE; synthetic peptides;
D O I
10.1016/S0022-1759(00)00295-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work we demonstrate the application of a commercial biosensor instrument (BIACORE 1000, Biacore AB, Uppsala) for the detection of antibodies against the hepatitis A virus (HAV) in human serum samples using linear and branched synthetic peptides related to the VP3 capsid protein of HAV. We also studied the conformation of the synthetic peptides by circular dichroism (CD) in order to analyse the changes in secondary structure of the constructs that could influence their recognition by antibodies. Linear and dimeric VP3(110-121) multiple antigen peptides (MAP) were the most sensitive and appropriate for serological studies of serum from HAV infected patients using BIACORE. Immobilization of tetrameric MAPs via amine groups apparently failed to preserve the active conformation of the peptide epitope since it led to lower antibody binding compared to linear and dimeric peptides. The CD analysis showed that the tetrameric MAP constructs tend to adopt a beta -sheet structure due to intermolecular aggregation, which limits epitope accessibility. Our results demonstrate the Value of biospecific interaction analysis technology using synthetic peptides for the diagnosis of acute hepatitis A. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 24
页数:12
相关论文
共 36 条
  • [1] DETERMINATION OF KINETIC CONSTANTS FOR THE INTERACTION BETWEEN A MONOCLONAL-ANTIBODY AND PEPTIDES USING SURFACE-PLASMON RESONANCE
    ALTSCHUH, D
    DUBS, MC
    WEISS, E
    ZEDERLUTZ, G
    VANREGENMORTEL, MHV
    [J]. BIOCHEMISTRY, 1992, 31 (27) : 6298 - 6304
  • [2] FIBER OPTIC EVANESCENT WAVE IMMUNOSENSORS FOR MEDICAL DIAGNOSTICS
    BLUESTEIN, BI
    WALCZAK, IM
    CHEN, SY
    [J]. TRENDS IN BIOTECHNOLOGY, 1990, 8 (06) : 161 - 168
  • [3] Synthesis of mono- and bifunctional peptide dextran conjugates for the immobilization of peptide antigens on ELISA plates:: properties and application
    Böcher, M
    Böldicke, T
    Kiess, M
    Bilitewski, U
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 208 (02) : 191 - 202
  • [4] Surface plasmon resonance analysis at a supported lipid monolayer
    Cooper, MA
    Try, AC
    Carroll, J
    Ellar, DJ
    Williams, DH
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1998, 1373 (01): : 101 - 111
  • [5] Restricted isotypic antibody reactivity to hepatitis C virus synthetic peptides in immunocompromised patients
    Devesa, M
    de Saez, A
    León, G
    Sirit, F
    Cosson, C
    Bermúdez, H
    Liprandi, F
    Noya, O
    Pujol, FH
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1999, 6 (02) : 279 - 281
  • [6] CONFORMATIONAL STUDY OF A SHORT PERTUSSIS TOXIN T-CELL EPITOPE INCORPORATED IN A MULTIPLE ANTIGEN PEPTIDE TEMPLATE BY CD AND 2-DIMENSIONAL NMR - ANALYSIS OF THE STRUCTURAL EFFECTS ON THE ACTIVITY OF SYNTHETIC IMMUNOGENS
    ESPOSITO, G
    FOGOLARI, F
    VIGLINO, P
    CATTARINUSSI, S
    DEMAGISTRIS, MT
    CHIAPPINELLI, L
    PESSI, A
    [J]. EUROPEAN JOURNAL OF BIOCHEMISTRY, 1993, 217 (01): : 171 - 187
  • [7] FIRSOVA T, 1998, PEPTIDES 1996, P383
  • [8] FRANCIS MJ, 1991, IMMUNOLOGY, V73, P249
  • [9] Garber Carl C., 1996, P402
  • [10] Use of linear and multiple antigenic peptides in the immunodiagnosis of acute hepatitis A virus infection
    Gómara, MJ
    Riedemann, S
    Vega, I
    Ibarra, H
    Ercilla, G
    Haro, I
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 234 (1-2) : 23 - 34