DNA cycle sequencing of a common restriction fragment of Staphylococcus aureus bacteriophages by capillary electrophoresis using replaceable linear polyacrylamide

被引:5
作者
Klepárník, K
Berka, J
Foret, F
Doskar, J
Kailerová, J
Rosypal, S
Bocek, P
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, CZ-61142 Brno, Czech Republic
[2] Masaryk Univ, Fac Sci, Dept Genet & Mol Biol, CS-61137 Brno, Czech Republic
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; Staphylococcus aureus bacteriophage; DNA cycle sequencing; linear polyacrylamide;
D O I
10.1002/elps.1150190516
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nucleotide sequence of a part of a 4.9 kbp common restriction fragment isolated from Staphylococcus aureus bacteriophage (bacterial virus) 3A has been determined by capillary electrophoresis (CE). The fast separation of sequencing fragments in linear polyacrylamide solution at a temperature of 55 degrees C allowed the reading of more than 650 bases of sequence in 60 min. The single strand (ss)DNA fragments were prepared by cycle sequencing with fluorescently labeled dideoxy-terminators on the cloned bacteriophage DNA template. With respect to analysis speed, sequence read-length, low sample consumption and automation, CE offers a simple, labor-saving and inexpensive procedure for DNA sequencing. Operating the CE columns at elevated temperature proved to be a rapid procedure capable of extending sequence read-length. The resulting sequence of the common restriction fragment can be used for the preparation of specific primers and oligonucleotide hybridization probes for identification of Staphylococcus aureus bacteriophages and/or prophages belonging to the bacteriophage species 3A.
引用
收藏
页码:695 / 700
页数:6
相关论文
共 41 条
[1]  
Ackermann H., 1987, Viruses of Prokaryotes: general properties of bacteriophages, V1
[2]   POLYMERIC SEPARATION MEDIA FOR ELECTROPHORESIS - CROSS-LINKED SYSTEMS OR ENTANGLED SOLUTIONS [J].
BAE, YC ;
SOANE, D .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) :17-22
[3]  
BAY S, 1994, J CAPIL ELECTROPHOR, V2, P121
[4]   SEPARATION OF FRAGMENTS UP TO 570 BASES IN LENGTH BY USE OF 6-PERCENT T-NON-CROSS-LINKED POLYACRYLAMIDE FOR DNA-SEQUENCING IN CAPILLARY ELECTROPHORESIS [J].
BEST, N ;
ARRIAGA, E ;
CHEN, DY ;
DOVICHI, NJ .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4063-4067
[5]   CAPILLARY ELECTROPHORESIS OF DNA IN AGAROSE SOLUTIONS AT 40-DEGREES-C [J].
BOCEK, P ;
CHRAMBACH, A .
ELECTROPHORESIS, 1991, 12 (12) :1059-1061
[6]  
Brandis H., 1984, STAPHYLOKOKKEN STAPH, P186
[7]   Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions [J].
Carrilho, E ;
RuizMartinez, MC ;
Berka, J ;
Smirnov, I ;
Goetzinger, W ;
Miller, AW ;
Brady, D ;
Karger, BL .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3305-3313
[8]   DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS - USE OF A 2-LASER 2-WINDOW INTENSIFIED DIODE-ARRAY DETECTION SYSTEM [J].
CARSON, S ;
COHEN, AS ;
BELENKII, A ;
RUIZMARTINEZ, MC ;
BERKA, J ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :3219-3226
[9]   SEPARATION AND ANALYSIS OF DNA-SEQUENCE REACTION-PRODUCTS BY CAPILLARY GEL-ELECTROPHORESIS [J].
COHEN, AS ;
NAJARIAN, DR ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :49-60
[10]   HIGH-SPEED SEPARATIONS OF DNA SEQUENCING REACTIONS BY CAPILLARY ELECTROPHORESIS [J].
DROSSMAN, H ;
LUCKEY, JA ;
KOSTICHKA, AJ ;
DCUNHA, J ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :900-903