Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation

被引:162
作者
Di Carlo, D [1 ]
Jeong, KH [1 ]
Lee, LP [1 ]
机构
[1] Univ Calif Berkeley, Dept Bioengn, Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
关键词
D O I
10.1039/b305162e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly effective, reagentless, mechanical cell lysis device integrated in microfluidic channels is reported. Sample preparation, specifically cell lysis, is a critical element in 'lab-on-chip' applications. However, traditional methods of cell lysis require purification steps or complicated fabrication steps that a simple mechanical method of lysis may avoid. A simple and effective mechanical cell lysis system is designed, microfabricated, and characterized to quantify the efficiency of cell lysis and biomolecule accessibility. The device functionality is based on a microfluidic filter region with nanostructured barbs created using a modified deep reactive ion etching process. Mechanical lysis is characterized by using a membrane impermeable dye. Three main mechanisms of micro-mechanical lysis are described. Quantitative measurements of accessible protein as compared to a chemically lysed sample are acquired with optical absorption measurements at 280 and 414 nm. At a flow rate of 300 muL min(-1) within the filter region total protein and hemoglobin accessibilities of 4.8% and 7.5% are observed respectively as compared to 1.9% and 3.2% for a filter without nanostructured barbs.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 13 条
[1]   Effect of lysing methods and their variables on the yield of Escherichia coli O157:H7 DNA and its PCR amplification [J].
Abolmaaty, A ;
El-Shemy, MG ;
Khallaf, MF ;
Levin, RE .
JOURNAL OF MICROBIOLOGICAL METHODS, 1998, 34 (02) :133-141
[2]   DEFORMATION AND FLOW OF RED-BLOOD-CELLS IN A SYNTHETIC LATTICE - EVIDENCE FOR AN ACTIVE CYTOSKELETON [J].
BRODY, JP ;
HAN, YQ ;
AUSTIN, RH ;
BITENSKY, M .
BIOPHYSICAL JOURNAL, 1995, 68 (06) :2224-2232
[3]   Self-sorting of white blood cells in a lattice [J].
Carlson, RH ;
Gabel, CV ;
Chan, SS ;
Austin, RH ;
Brody, JP ;
Winkelman, JW .
PHYSICAL REVIEW LETTERS, 1997, 79 (11) :2149-2152
[4]   Preparation and hybridization analysis of DNA/RNA from E-coli on microfabricated bioelectronic chips [J].
Cheng, J ;
Sheldon, EL ;
Wu, L ;
Uribe, A ;
Gerrue, LO ;
Carrino, J ;
Heller, MJ ;
O'Connell, JP .
NATURE BIOTECHNOLOGY, 1998, 16 (06) :541-546
[5]   In vitro human scleral permeability of fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein and rhodamine 6G and the use of a coated coil as a new drug delivery system [J].
Cruysberg, LPJ ;
Nuijts, RMMA ;
Geroski, DH ;
Koole, LH ;
Hendrikse, F ;
Edelhauser, HF .
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2002, 18 (06) :559-569
[6]   MEMS-based sample preparation for molecular diagnostics [J].
Huang, Y ;
Mather, EL ;
Bell, JL ;
Madou, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :49-65
[7]   A micro cell lysis device [J].
Lee, SW ;
Tai, YC .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 73 (1-2) :74-79
[8]   Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects [J].
Li, PCH ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1564-1568
[9]   Mechanical haemolysis in shock wave lithotripsy (SWL):: II.: In vitro cell lysis due to shear [J].
Lokhandwalla, M ;
McAteer, JA ;
Williams, JC ;
Sturtevant, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :1245-1264
[10]   Micromachining technology for lateral field emission devices [J].
Milanovic, V ;
Doherty, L ;
Teasdale, DA ;
Parsa, S ;
Pister, KSJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2001, 48 (01) :166-173