Neonatal hydrocephalus: Hemodynamic response to fontanelle compression - Correlation with intracranial pressure and need for shunt placement

被引:63
作者
Taylor, GA
Madsen, JR
机构
[1] CHILDRENS HOSP, DEPT NEUROSURG, BOSTON, MA 02115 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
brain; hydrocephalus; blood flow; US;
D O I
10.1148/radiology.201.3.8939216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether the hemodynamic response to fontanelle compression during Doppler sonography can be used to indirectly assess intracranial pressure and help determine the need for shunt placement in hydrocephalic infants. MATERIALS AND METHODS: Sixty Doppler sonographic examinations were performed to obtain resistive indexes before and during fontanelle compression in 14 hydrocephalic infants. Twenty-five intracranial pressure measurements were obtained in 12 infants during cerebrospinal fluid removal and correlated with the change in resistive index during compression of the anterior fontanelle. RESULTS: Baseline resistive index without fontanelle compression was not correlated with intracranial pressure (r = .1, P = .63). A statistically significant correlation was found between the change in resistive index during compression and elevated intracranial pressure (r = .8, P < .0001). Maximum change in resistive index was significantly higher (P < .001) in infants who subsequently required surgical intervention (mean [+/- standard deviation], 74% +/- 9; range, 47%-132%) than in infants who did not require ventricular drainage (mean, 19% +/- 6; range, 3%-29%, P < .0003). CONCLUSION: Hemodynamic response to fontanelle compression can be used as a noninvasive predictor of progressive or persistently elevated intracranial pressure in newborns with hydrocephalus and may be helpful in predicting need for shunt placement.
引用
收藏
页码:685 / 689
页数:5
相关论文
共 22 条
  • [11] HILL A, 1982, PEDIATRICS, V69, P4
  • [12] ABSOLUTE INTRACRANIAL BLOOD-FLOW VELOCITIES EVALUATED BY DUPLEX DOPPLER SONOGRAPHY IN ASYMPTOMATIC PRETERM AND TERM NEONATES
    HORGAN, JG
    RUMACK, CM
    HAY, T
    MANCOJOHNSON, ML
    MERENSTEIN, GB
    ESOLA, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) : 1059 - 1064
  • [13] CEREBRAL BLOOD-FLOW VELOCITY PATTERNS IN POSTHEMORRHAGIC VENTRICULAR DILATION
    LUI, K
    HELLMANN, J
    SPRIGG, A
    DANEMAN, A
    [J]. CHILDS NERVOUS SYSTEM, 1990, 6 (05) : 250 - 253
  • [14] DUPLEX PULSED DOPPLER ULTRASONOGRAPHY VERSUS INTRACRANIAL-PRESSURE IN THE NEONATE - CLINICAL AND EXPERIMENTAL STUDIES
    SEIBERT, JJ
    MCCOWAN, TC
    CHADDUCK, WM
    ADAMETZ, JR
    GLASIER, CM
    WILLIAMSON, SL
    TAYLOR, BJ
    LEITHISER, RE
    MCCONNELL, JR
    STANSELL, CA
    RODGERS, AB
    CORBITT, SL
    [J]. RADIOLOGY, 1989, 171 (01) : 155 - 159
  • [15] BIOMECHANICAL AND HYDRODYNAMIC CHARACTERIZATION OF THE HYDROCEPHALIC INFANT
    SHAPIRO, K
    FRIED, A
    MARMAROU, A
    [J]. JOURNAL OF NEUROSURGERY, 1985, 63 (01) : 69 - 75
  • [16] INTRACRANIAL COMPLIANCE IN INFANTS - EVALUATION WITH DOPPLER US
    TAYLOR, GA
    PHILLIPS, MD
    ICHORD, RN
    CARSON, BS
    GATES, JA
    JAMES, CS
    [J]. RADIOLOGY, 1994, 191 (03) : 787 - 791
  • [17] EFFECT OF SCANNING PRESSURE ON INTRACRANIAL HEMODYNAMICS DURING TRANSFONTANELLAR DUPLEX US
    TAYLOR, GA
    [J]. RADIOLOGY, 1992, 185 (03) : 763 - 766
  • [18] INTRACRANIAL BLOOD-FLOW - QUANTIFICATION WITH DUPLEX DOPPLER AND COLOR DOPPLER FLOW US
    TAYLOR, GA
    SHORT, BL
    WALKER, LK
    TRAYSTMAN, RJ
    [J]. RADIOLOGY, 1990, 176 (01) : 231 - 236
  • [19] TAYLOR GA, 1992, ULTRASOUND Q, V4, P223
  • [20] CONCURRENT CHANGES IN INTRACRANIAL-PRESSURE, CEREBRAL BLOOD-FLOW VELOCITY, AND BRAIN ENERGY-METABOLISM IN RABBITS WITH ACUTE INTRACRANIAL HYPERTENSION
    TRANQUART, F
    DEBRAY, JM
    BERSON, M
    AKOKA, S
    BODARD, S
    POURCELOT, L
    [J]. CHILDS NERVOUS SYSTEM, 1994, 10 (05) : 285 - 292