Comparison of pulsed electrochemical detection modes coupled with microchip capillary electrophoresis

被引:24
作者
García, CD [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
microchip capillary electrophoresis; pulsed electrochemical detection; pulsed amperometric detection; carbohydrate; SDS;
D O I
10.1002/elan.200403083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a need to develop analytical methods that are capable of rapidly measuring small biological markers in the field of metabolomics. Among others, carbohydrates play an important role biologically yet are traditionally hard to detect since they have no chromophore or fluorophore. In the present report, the first application of integrated pulsed amperometric detection (iPAD) coupled with microchip electrophoresis to the analysis of glucose, mannose, sucrose, maltose. glucosamine, lactose, maltotriose and galactose is demonstrated. WAD is an electrochemical detection mode that can be used for direct detection of carbohydrates, amines and sulfur containing compounds. The effect of different solution parameters, including the buffer concentration, pH and the concentration of SDS on both separation and detection response was analyzed. In addition, a comparison study between PAD and WAD was performed using glucose, glucosamine, sucrose and maltose as model carbohydrates.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 75 条
[71]   Determination of carbohydrates as their p-sulfophenylhydrazones by capillary zone electrophoresis [J].
Wang, XY ;
Chen, Y .
CARBOHYDRATE RESEARCH, 2001, 332 (02) :191-196
[72]   Capillary electrophoresis with pulsed amperometric detection of carbohydrates and glycopeptides [J].
Weber, PL ;
Lunte, SM .
ELECTROPHORESIS, 1996, 17 (02) :302-309
[73]   Electrophoresis in nanometer inner diameter capillaries with electrochemical detection [J].
Woods, LA ;
Roddy, TP ;
Paxon, TL ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3687-3690
[74]   The electroanalysis of mannitol, xylose and lactulose at copper electrodes: voltammetric studies and bioanalysis in human urine by means of HPLC with electrochemical detection [J].
Wring, SA ;
Terry, A ;
Causon, R ;
Jenner, WN .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (07) :1213-1224
[75]   Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection [J].
Wu, CC ;
Wu, RG ;
Huang, JG ;
Lin, YC ;
Chang, HC .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :947-952