On the relationship between encapsulated ultrasound contrast agent and pressure

被引:45
作者
Adam, D [1 ]
Sapunar, M [1 ]
Burla, E [1 ]
机构
[1] Technion Israel Inst Technol, Dept Biomed Engn, IL-32000 Haifa, Israel
关键词
ultrasound; contrast agent; pressure estimation; cardiovascular;
D O I
10.1016/j.ultrasmedbio.2005.01.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Noninvasive measurement of pressure within the heart cavities and other internal organs (e.g., kidney, liver) has significant clinical value, but currently is not feasible. Noninvasive pressure estimation using encapsulated ultrasound (US) contrast agents (UCA) as sensors is a challenge because they supposedly respond to their ambient pressure, but they are more rigid and less sensitive to pressure than gas microbubbles. Here, Optison sensitivity was studied (f(resonance) = approximate to 2 MHz) to varying pressures, when excited at 2 times and also at 0.5 times f(resonance). Cyclic momentary increases in ambient pressure of 0 to 5, 0 to 10, 0 to 15 or 0 to 20 kPa at 1.0 Hz, mimicking left ventricular (LV) pressure changes, caused amplitude decrease of echoes at 0.5, 1 and 2 times the transmitted frequency and decrease of attenuation. Changes at 0.5 times the transmitted frequency correlated best, but only after 70 to 150 s. The correlations (mean SD) during 150 to 300 s were 0.706 +/- 0.072 for 0 to 10 kPa, 0.844 +/- 0.042 for 0 to 15 kPa and 0.859 +/- 0.031 for 0 to 20 kPa. Attenuation presented less correlation. For 1.0 Hz, 10 to 15 kPa or 15 to 20 kPa pressures, mimicking systemic pressures, the attenuation decayed fast and even faster for slow (0.05 Hz) cyclic varying pressures, or elevated steady-state pressures (of 10 kPa and 20 kPa). Thus, cyclic pressure effects on UCA are demonstrated to be reversible, but elevated static pressures cause UCA destruction. This allows cyclic pressure variations to be detected, using the subharmonics of the transmitted frequency, down to 10 kPa.(c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:673 / 686
页数:14
相关论文
共 31 条
[1]   Noninvasive measurement of the hydrostatic pressure in a fluid-filled cavity based on the disappearance time of micrometer-sized free gas bubbles [J].
Bouakaz, A ;
Frinking, PJA ;
de Jong, N ;
Bom, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1407-1415
[2]   On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent [J].
Bouakaz, A ;
de Jong, N ;
Cachard, C ;
Jouini, K .
ULTRASONICS, 1998, 36 (1-5) :703-708
[3]   Effect of static pressure on acoustic transmittance of Albunex(R) microbubble suspensions [J].
Brayman, AA ;
Azadniv, M ;
Miller, MW ;
Meltzer, RS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (04) :2403-2408
[4]   Pressure-dependent attenuation in ultrasound contrast agents [J].
Chen, Q ;
Zagzebski, J ;
Wilson, T ;
Stiles, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (08) :1041-1051
[5]  
CHEN WH, 1998, P 1998 IEEE ULTR S, V2, P1791
[6]   Nondestructive subharmonic imaging [J].
Chomas, J ;
Dayton, P ;
May, D ;
Ferrara, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) :883-892
[7]   Optical imaging of contrast agent microbubbles in an ultrasound field with a 100-MHz camera [J].
de Jong, N ;
Frinking, PJA ;
Bouakaz, A ;
Goorden, M ;
Schourmans, T ;
Xu, JP ;
Mastik, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :487-492
[8]  
DEJONG N, 1993, ULTRASOUND MED BIOL, V19, P279, DOI 10.1016/0301-5629(93)90100-3
[9]   NEW NONINVASIVE TECHNIQUE FOR CARDIAC PRESSURE MEASUREMENT - RESONANT SCATTERING OF ULTRASOUND FROM BUBBLES [J].
FAIRBANK, WM ;
SCULLY, MO .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1977, 24 (02) :107-110
[10]   A new ultrasound contrast imaging approach based on the combination of multiple imaging pulses and a separate release burst [J].
Frinking, PJA ;
Céspedes, EI ;
Kirkhorn, J ;
Torp, HG ;
de Jong, N .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (03) :643-651