Speciation of Cr(III) and Cr(VI) in environmental samples after solid phase extraction on amberlite XAD-2000

被引:25
作者
Duran, Celal
Soylak, Mustafa [1 ]
Bulut, Volkan Numan
Gundogdu, Ali
Tufekci, Mehmet
Elcid, Latif
Senturk, Hasan Basri
机构
[1] Erciyes Univ, Fac Art & Sci, Dept Chem, TR-38039 Kayseri, Turkey
[2] Karadeniz Tech Univ, Dept Chem, Fac Arts & Sci, TR-61080 Trabzon, Turkey
[3] Karadeniz Tech Univ, Giresun Fac Art & Sci, Dept Chem, TR-28049 Giresun, Turkey
[4] Pamukkale Univ, Fac Arts & Sci, Dept Chem, TR-20020 Denizli, Turkey
关键词
chromium speciation; preconcentration; APDC; amberlite XAD-2000; FAAS;
D O I
10.1002/jccs.200700090
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbarnate (APDC) complex by using a column containing Amberlite XAD-2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow-rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5-2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g(-1) Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 mu g/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM-TMDW-500 (Certified Reference Material Trace Metals in Drinking Water) and BCR-CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.
引用
收藏
页码:625 / 634
页数:10
相关论文
共 38 条
[11]   METAL SPECIATION BY MEANS OF MICROBORE COLUMNS WITH DIRECT-INJECTION NEBULIZATION BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY [J].
GJERDE, DT ;
WIEDERIN, DR ;
SMITH, FG ;
MATTSON, BM .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :73-78
[12]   Speciation of chromium(VI) and chromium(III) using pneumatically assisted electrospray mass spectrometry [J].
Gwizdala, AB ;
Johnson, SK ;
Mollah, S ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :503-506
[13]  
HADJILIADIS ND, 1996, CYTOTOXIC MUTAGENIC
[14]   Determination of some metal ions in aquatic environs by atomic absorption spectrometry after concentration with modified silica [J].
Hamed, Mohamed A. ;
Abou-El-Sherbini, Khaled S. ;
Lotfy, Hesham R. .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2006, 53 (03) :605-612
[15]   PRECONCENTRATION OF METAL-IONS WITH ANION-EXCHANGE RESIN [J].
JEN, JF ;
FU, JT .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1993, 40 (03) :245-250
[16]  
Landgraf W., 2003, DRUG DELIVERY TECHNO, V3, P1
[18]   ATOMIC-ABSORPTION SPECTROPHOTOMETRIC DETERMINATION OF COPPER (I) AFTER ADSORPTION OF ITS 4'-(P-METHOXYPHENYL)-2,2' - 6',2''-TERPYRIDINE TETRAPHENYLBORATE ION-ASSOCIATED COMPLEX ON MICROCRYSTALLINE NAPHTHALENE [J].
LIN, JL ;
SATAKE, M .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1985, 32 (02) :105-109
[19]   PRECONCENTRATION OF TRACE-ELEMENTS IN WATER FOR SPECIATION STUDIES [J].
MIZUIKE, A .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1990, 37 (02) :117-124
[20]   Preconcentration, determination and speciation of chromium(III) using solid phase extraction and flame atomic absorption spectrometry [J].
Mohammadhosseini, Majid ;
Tehrani, Mohammad Saber ;
Ganjali, Mohammad Reza .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2006, 53 (03) :549-557