Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm

被引:28
作者
Daugherty, DW [1 ]
Gound, TG [1 ]
Comer, TL [1 ]
机构
[1] Univ Nebraska, Med Ctr, Coll Dent, Lincoln, NE 68583 USA
关键词
D O I
10.1097/00004770-200102000-00008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Two groups of 30 mature molars each (S and F) were instrumented with Profile .04 taper Series 29 rotary instruments. Group S molars were instrumented at 150 rpm and group F at 350 rpm. The number of fractures, deformed files, and instrumentation time were recorded for each tooth. No instrument fractures occurred in either group, In group S the mean deformation rate and instrumentation time were 1.1 deformed files and 8.0 min per molar. In group F they were 0.57 deformed files and 4.6 min per molar. Both differences were significant (p < 0.05), The results indicate that Profile .04 taper Series 29 rotary instruments should be used at 350 rpm to nearly double efficiency and halve the deformation rate, compared with 150 rpm. Because no instrument fractures occurred while instrumenting 60 mature molars, both speeds should be considered safe.
引用
收藏
页码:93 / 95
页数:3
相关论文
共 13 条
[1]   A RADIOGRAPHIC COMPARISON OF 2 ROOT-CANAL INSTRUMENTATION TECHNIQUES [J].
BACKMAN, CA ;
OSWALD, RJ ;
PITTS, DL .
JOURNAL OF ENDODONTICS, 1992, 18 (01) :19-24
[2]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[3]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[4]   EFFECT OF NICKEL-TITANIUM ENGINE-DRIVEN INSTRUMENT ROTATIONAL SPEED ON ROOT-CANAL MORPHOLOGY [J].
POULSEN, WB ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (12) :609-612
[5]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[6]   Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files [J].
Silvaggio, J ;
Hicks, ML .
JOURNAL OF ENDODONTICS, 1997, 23 (12) :731-734
[7]   INSTRUMENTATION OF CURVED MOLAR ROOT CANALS WITH THE ROANE TECHNIQUE [J].
SOUTHARD, DW ;
OSWALD, RJ ;
NATKIN, E .
JOURNAL OF ENDODONTICS, 1987, 13 (10) :479-489
[8]   Properties of endodontic hand instruments used in rotary motion .3. Resistance to bending and fracture [J].
Tepel, J ;
Schafer, E ;
Hoppe, W .
JOURNAL OF ENDODONTICS, 1997, 23 (03) :141-145
[9]   Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals .2. [J].
Thompson, SA ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :8-15
[10]  
Thompson SA, 1997, INT ENDOD J, V30, P1, DOI 10.1111/j.1365-2591.1997.tb01093.x