Whole-heart coronary magnetic resonance angiography - Contrast-enhanced high-resolution, time-resolved 3D imaging

被引:14
作者
Warmuth, Carsten
Schnorr, Joerg
Kaufels, Nicola
Wagner, Susanne
Pilgrimm, Herbert
Hamm, Bernd
Taupitz, Matthias
机构
[1] Charite Univ Med Berlin, Dept Radiol, D-10098 Berlin, Germany
[2] Ferropharm GmbH, Forschungslabor, Teltow, Germany
关键词
coronary angiography; blood pool contrast medium; iron oxide;
D O I
10.1097/RLI.0b013e31803c4a5a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To test the feasibility and performance of a 4D magnetic resonance coronary angiography sequence compared with conventional inversion recovery (IR) prepared gradient echo imaging. Materials and Methods: A 4D sequence with 100 milliseconds temporal resolution was implemented on a 1.5 T system. Five minipigs were examined after administration of very small superparamagnetic iron oxide particles. Coronary angiographies with an isotropic resolution of 0.82 mm were performed in the pigs using 4D and IR sequences. Results: The 4D sequence allowed visualization of the coronary arteries, the effect of their movement and that of the entire heart without prolonging scan time. The contrast-to-noise ratio of the IR images was on average 38% higher than that of the corresponding 4D phase. Conclusions: 4D magnetic resonance imaging is superior in that no trigger delay time needs to be determined and an additional whole-heart cine study can be obtained.
引用
收藏
页码:550 / 557
页数:8
相关论文
共 26 条
[1]  
Alley MT, 1999, JMRI-J MAGN RESON IM, V9, P751, DOI 10.1002/(SICI)1522-2586(199905)9:5<751::AID-JMRI21>3.0.CO
[2]  
2-7
[3]   Contrast-enhanced 4D radial coronary artery imaging at 3.0 T within a single breath-hold [J].
Bi, XM ;
Park, J ;
Larson, AC ;
Zhang, Q ;
Simonetti, O ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :470-475
[4]   Computed tomography coronary angiography with 370-millisecond gantry rotation time - Evaluation of the best image reconstruction interval [J].
Bley, TA ;
Ghanem, NA ;
Foell, D ;
Uhl, M ;
Geibel, A ;
Bode, C ;
Langer, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) :1-5
[5]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[6]   Comparison of gradient-echo and steady-state free precession for coronary artery magnetic resonance angiography using a gadolinium-based intravascular contrast agent [J].
Deshpande, VS ;
Cavagna, F ;
Maggioni, F ;
Schirf, BE ;
Omary, RA ;
Li, DB .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :292-298
[7]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[8]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97