Computed tomography coronary angiography with 370-millisecond gantry rotation time - Evaluation of the best image reconstruction interval

被引:41
作者
Bley, TA
Ghanem, NA
Foell, D
Uhl, M
Geibel, A
Bode, C
Langer, M
机构
[1] Univ Freiburg, Dept Cardiol, Freiburg, Germany
[2] Univ Freiburg, Dept Radiol, Freiburg, Germany
关键词
coronary vessels; heart; computed tomography; angiography; image quality;
D O I
10.1097/01.rct.0000149234.09647.8c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the best reconstruction window for noninvasive coronary angiography when using a 16-detector row computed tomography (CT) scanner with a gantry rotation time of 370 milliseconds. Methods: In a pilot study, 189 coronary artery segments of 21 patients with a mean heart rate of 65 beats per minute (bpm, maximum: 45-94 bpm) were investigated using a 16-detector row CT scanner. Raw data were reconstructed in 10% increments from 40% to 70% of the RR interval. Two experienced observers independently evaluated the image quality of the coronary arteries in a segmental fashion. A 5-point ranking scale was applied, with 1 being very poor (no evaluation possible); 2, poor; 3, moderate; 4, good; and 5, very good. Results: In the mean of all patients, the best reconstruction window was found to be at 60% of the RR interval. In patients with higher heart rates, the best reconstruction window was found to be at an earlier stage of the R wave-to-R wave interval. Conclusions: Initial results show that good diagnostic image quality could be achieved for all evaluated segments of the coronary tree with image reconstructions at 60% of the R wave-to-R wave interval in patients with heart rates of 70 bpm or less. Using a 16-detector row CT scanner with a gantry rotation time of 370 milliseconds, the need for adapting the reconstruction window to each segment for the best image quality was overcome in those cases. In patients with heart rates faster than 70 bpm, reconstructions at an earlier stage within the cardiac cycle were necessary.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 14 条
  • [1] Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography
    Achenbach, S
    Giesler, T
    Ropers, D
    Ulzheimer, S
    Anders, K
    Wenkel, E
    Pohle, K
    Kachelriess, M
    Derlien, H
    Kalender, WA
    Daniel, WG
    Bautz, W
    Baum, U
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (02) : 119 - 128
  • [2] Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection
    Giesler, T
    Baum, U
    Ropers, D
    Ulzheimer, S
    Wenkel, E
    Mennicke, M
    Bautz, W
    Kalender, WA
    Daniel, WG
    Achenbach, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 911 - 916
  • [3] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [4] Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Heuschmid, M
    Georg, C
    Ohnesorge, B
    Kuzo, R
    Claussen, CD
    [J]. RADIOLOGY, 2001, 221 (03) : 683 - 688
  • [5] Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound
    Kopp, AF
    Schroeder, S
    Baumbach, A
    Kuettner, A
    Georg, C
    Ohnesorge, B
    Heuschmid, M
    Kuzo, R
    Claussen, CD
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (09) : 1607 - 1611
  • [6] Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    Nieman, K
    Cademartiri, F
    Lemos, PA
    Raaijmakers, R
    Pattynama, PMT
    de Feyter, PJ
    [J]. CIRCULATION, 2002, 106 (16) : 2051 - 2054
  • [7] Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate
    Nieman, K
    Rensing, BJ
    van Geuns, RJM
    Vos, J
    Pattynama, PMT
    Krestin, GP
    Serruys, PW
    de Feyter, PJ
    [J]. HEART, 2002, 88 (05) : 470 - 474
  • [8] Current concepts in multi-detector row CT evaluation of the coronary arteries: Principles, techniques, and anatomy
    Pannu, HK
    Flohr, TG
    Corl, FM
    Fishman, EK
    [J]. RADIOGRAPHICS, 2003, 23 : S111 - S125
  • [9] Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    Ropers, D
    Baum, U
    Pohle, K
    Anders, K
    Ulzheimer, S
    Ohnesorge, B
    Schlundt, C
    Bautz, W
    Daniel, WG
    Achenbach, S
    [J]. CIRCULATION, 2003, 107 (05) : 664 - 666
  • [10] Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound
    Schoenhagen, P
    Tuzcu, EM
    Stillman, AE
    Moliterno, DJ
    Halliburton, SS
    Kuzmiak, SA
    Kasper, JM
    Magyar, WA
    Lieber, ML
    Nissen, SE
    White, RD
    [J]. CORONARY ARTERY DISEASE, 2003, 14 (06) : 459 - 462