A new functionalized resin and its application in preconcentration system with multivariate optimization for nickel determination in food samples

被引:44
作者
Lemos, VA [1 ]
Baliza, PX [1 ]
Santos, JS [1 ]
Nunes, LS [1 ]
de Jesus, AA [1 ]
Rocha, ME [1 ]
机构
[1] Univ Estadual Sudoeste Bahia, LQA, NQA, BR-45200000 Jequie, BA, Brazil
关键词
nickel; synthesis; multivariate optimization; preconcentration; amberlite XAD-2;
D O I
10.1016/j.talanta.2004.11.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, Amberlite XAD-2 resin functionalized with 4,5-dihydroxy-1,3-benzenedisulfonic acid was synthesized, characterized and applied as a new packing material for an on-line system to nickel preconcentration. The method is based on the sorption of Ni(II) ions in a minicolumm containing the synthesized resin, posterior desorption using an acid solution and measurement of the nickel by spectrophotometry (PAR method). The optimization of the system was performed using factorial design and Doehlert matrix considering five variables: eluent concentration, PAR solution pH, sample flow rate, PAR solution concentration and sample pH. Signals were measured as peak height by using an instrument software. Using the experimental conditions defined in the optimization, the method allowed nickel determination with achieved sampling rate of 25 samples per hour, detection limit (3 s) of 2 mu g 1(-1) and precision (assessed as the relative standard deviation) of 8.2-2.6%, for nickel solutions of 10.0-200.0 mu g 1(-1) concentration, respectively. The experimental enrichment factor of the proposed system was 46, for 120 s preconcentration time. The proposed procedure was applied for nickel determination in food samples. Recoveries of spike additions (5 or 10 mu g g(-1)) to food samples were quantitative (94-110%). (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 41 条
[1]   Determination of nickel after online sorbent preconcentration by FI-FAAS using dimethylglyoxime as a complexing agent [J].
Ali, A ;
Ye, YX ;
Xu, GM ;
Yin, XF ;
Zhang, T .
MICROCHEMICAL JOURNAL, 1999, 63 (03) :365-373
[2]   Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) :798-803
[3]   Experimental designs applied to solid-phase derivative spectrophotometry [J].
Bosque-Sendra, JM ;
Nechar, M ;
Molina, MF .
MIKROCHIMICA ACTA, 2000, 134 (1-2) :43-50
[4]   Fluorimetric determination of aluminium in water by sequential injection through column extraction [J].
Brach-Papa, C ;
Coulomb, B ;
Branger, C ;
Margaillan, A ;
Théraulaz, F ;
Van Loot, P ;
Boudenne, JL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) :1652-1658
[5]   Polyurethane foams as solid chromogenic reagents for diffuse reflectance spectroscopy [J].
Dmitrienko, SG ;
Sviridova, OA ;
Pyatkova, LN ;
Senyavin, VM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :361-368
[6]  
Doehlert D.H., 1970, Appl. Stat, V19, P231
[7]  
Dogutan M, 2000, SEPAR SCI TECHNOL, V35, P2083
[8]   Preconcentration of manganese(II) from natural and sea water on a palmitoyl quinolin-8-ol functionalized XAD copolymer resin and spectrophotometric determination with the formaldoxime reagent [J].
Dogutan, M ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2003, 485 (02) :205-212
[9]   Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery [J].
dos Santos, WL ;
dos Santos, CMM ;
Costa, JLO ;
Andrade, HMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2004, 77 (02) :123-129
[10]   The chromatographic behavior of group (IIB) metal ions on polyurethane foam functionalized with 8-hydroxyquinoline [J].
El-Shahat, MF ;
Moawed, EA ;
Zaid, MAA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :470-478