Automatic accurate non-invasive quantitation of blood flow, cross-sectional vessel area, and wall shear stress by modelling of magnetic resonance velocity data

被引:29
作者
Oyre, S [1 ]
Paaske, WP [1 ]
Ringgaard, S [1 ]
Kozerke, S [1 ]
Erlandsen, M [1 ]
Boesiger, P [1 ]
Pedersen, EM [1 ]
机构
[1] Aarhus Univ Hosp, Skejby Sygehus, Dept Cardiothorac & Vasc Surg T, DK-8200 Aarhus N, Denmark
关键词
blood flow; carotid artery; haemodynamics; magnetic resonance imaging; wall shear stress;
D O I
10.1016/S1078-5884(98)80244-X
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to apply a new, automatic and non-invasive method for quantification of blood flow, dynamic mass-sectional vessel area, and wall shear stress (WSS) by in vivo magnetic resonance velocity mapping of normal subjects. Design: prospective, open study. Materials: six young volunteers. Methods: a three-dimensional paraboloid model enabling automatic determination of bloodflow, vessel distensibility and WSS was applied to blood velocity determinations in the common carotid artery. Blood flow was also determined by a manual edge detection method. Results: using the new method, the common carotid mean blood flow was 7.28 (5.61-9.63) (mean (range)) ml/s. By;the manual method blood flow was 7.21 (5.55-9.60) ml/s. Mean luminal vessel area was 26% larger in peak systole than in diastole. Mean/peak WSS was 0.82/2.28 N/m(2). Manually and automatically determined flows correlated (r(2) = 0.998, p < 0.0001). WSS and peak centre velocity were associated (r(2) = 0.805, p < 0.0001). Conclusions: bloodflow, luminal vessel area dilatation, and WSS can be determined by the automatic three-dimensional paraboloid method. The hypothesis of association between peak centre velocity and WSS was not contradicted by the results of the present study.
引用
收藏
页码:517 / 524
页数:8
相关论文
共 29 条
[11]   LEFT-VENTRICULAR BLOOD-FLOW PATTERNS IN NORMAL SUBJECTS - A QUANTITATIVE-ANALYSIS BY 3-DIMENSIONAL MAGNETIC-RESONANCE VELOCITY MAPPING [J].
KIM, WY ;
WALKER, PG ;
PEDERSEN, EM ;
POULSEN, PK ;
OYRE, S ;
HOULIND, K ;
YOGANATHAN, AP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (01) :224-238
[12]  
LANNE T, 1994, J VASC SURG, V20, P218
[13]   A COMPUTER-SIMULATION OF THE NON-NEWTONIAN BLOOD-FLOW AT THE AORTIC BIFURCATION [J].
LOU, Z ;
YANG, WJ .
JOURNAL OF BIOMECHANICS, 1993, 26 (01) :37-49
[14]   Accurate velocity mapping with FAcE [J].
Maier, SE ;
Scheidegger, MB ;
Lu, KC ;
Boesiger, P .
MAGNETIC RESONANCE IMAGING, 1996, 14 (02) :163-171
[15]   HUMAN ABDOMINAL-AORTA - COMPARATIVE MEASUREMENTS OF BLOOD-FLOW WITH MR IMAGING AND MULTIGATED DOPPLER US [J].
MAIER, SE ;
MEIER, D ;
BOESIGER, P ;
MOSER, UT ;
VIELI, A .
RADIOLOGY, 1989, 171 (02) :487-492
[16]   Renal artery velocity mapping with MR imaging [J].
Maier, SE ;
Scheidegger, MB ;
Liu, KC ;
Schneider, E ;
Bollinger, A ;
Boesiger, P .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :669-676
[17]   MR flow quantification using RACE: Clinical application to the carotid arteries [J].
Moller, HE ;
Klocke, HK ;
Bongartz, GM ;
Peters, PE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03) :503-512
[18]  
Nichols W.W., 1990, MCDONALDS BLOOD FLOW
[19]  
Oshinski JN, 1995, JMRI-J MAGN RESON IM, V5, P640
[20]   In vivo wall shear stress measured by magnetic resonance velocity mapping in the normal human abdominal aorta [J].
Oyre, S ;
Pedersen, EM ;
Ringgaard, S ;
Boesiger, P ;
Paaske, WP .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (03) :263-271