Load shift of the intervertebral disc after a vertebroplasty: a finite-element study

被引:261
作者
Baroud, G
Nemes, J
Heini, P
Steffen, T
机构
[1] McGill Univ, Royal Victoria Hosp, Div Orthopaed Surg, Orthopaed Res Lab, Montreal, PQ H3A 1A1, Canada
[2] McGill Univ, Dept Mech Engn, Montreal, PQ H3A 2T5, Canada
[3] Univ Bern, Inselspital, Dept Orthopaed Surg, Spine Serv, CH-3010 Bern, Switzerland
关键词
cement augmentation; vertebroplasty; complications; adjacent fractures; load shift; finite-element modeling;
D O I
10.1007/s00586-002-0512-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Infiltrating osteoporotic cancellous bone with bone cement (vertebroplasty) is a novel surgical procedure to stabilize and prevent osteoporotic vertebral fractures. Short-term clinical and biomechanical results are encouraging; however, so far no reports on long-term results have been published. Our clinical observations suggest that vertebroplasty may induce subsequent fractures in the vertebrae adjacent to the ones augmented. At this point, there is only a limited understanding of what causes these fractures. We have previously hypothesized that adjacent fractures may result from a shift in stiffness and load following rigid augmentation. The purpose of this study is to determine the load shift in a lumbar motion segment following vertebroplasty. A finite-element (FE) model of a lumbar motion segment (L4-L5) was used to quantify and compare the pre- and post-augmentation stiffness and loading (load shift) of the intervertebral (IV) disc adjacent to the augmented vertebra in response to quasi-static compression. The results showed that the rigid cement augmentation underneath the endplates acted as an upright pillar that severely reduced the inward bulge of the endplates of the augmented vertebra. The bulge of the augmented endplate was reduced to 7% of its value before the augmentation, resulting in a stiffening of the IV joint by approximately 17%, and of the whole motion segment by approximately 11%. The IV pressure accordingly increased by approximately 19%, and the inward bulge of the endplate adjacent to the one augmented (L4 inferior) increased considerably, by approximately 17%. This increase of up to 17% in the inward bulge of the endplate adjacent to the one augmented may be the cause of the adjacent fractures.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 21 条
[1]   THE EFFECT OF POSTURE ON THE FLUID CONTENT OF LUMBAR INTERVERTEBRAL DISKS [J].
ADAMS, MA ;
HUTTON, WC .
SPINE, 1983, 8 (06) :665-671
[2]  
Baroud G., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P133, DOI 10.1080/1025584031000095746
[3]  
BAROUD G, 2001, P 18 C INT SOC BIOM, P728
[4]  
BAROUD G, 1997, BIOMED TECH, V43, P25
[5]   Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[6]   Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[7]   DEFORMATION OF THE VERTEBRAL ENDPLATE UNDER AXIAL LOADING OF THE SPINE [J].
BRINCKMANN, P ;
FROBIN, W ;
HIERHOLZER, E ;
HORST, M .
SPINE, 1983, 8 (08) :851-856
[8]   Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320
[9]  
EBERLEIN R, 1998, COMPUT METHODS BIOME, V4, P209
[10]  
FERGUSON S, 2001, P 47 ANN M ORTH RES, P280