A comparison of conventional and fast spin-echo sequences for the measurement of lesion load in multiple sclerosis using a semi-automated contour technique

被引:26
作者
Rovaris, M [1 ]
GawneCain, ML [1 ]
Wang, L [1 ]
Miller, DH [1 ]
机构
[1] UCL NATL HOSP NEUROL & NEUROSURG, NMR RES INST, NEUROL INST, LONDON WC1N 3BG, ENGLAND
关键词
magnetic resonance imaging; multiple sclerosis; pulse sequences; lesion load;
D O I
10.1007/s002340050384
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Changes on serial assessments of brain MRI lesion load are used for monitoring therapeutic efficacy in patients with multiple sclerosis (MS). We assessed the accuracy and reliability of conventional spin-echo (CSE) and fast spin-echo (FSE) sequences for measurement of lesion volume using a semiautomated contour technique. Cranial CSE and FSE examinations of 18 patients with secondary progressive MS were studied. The mean lesion load was slightly higher with the CSE sequence (p = 0.002). Intraobserver variability was significantly higher for FSE than for CSE, according to both the coefficient of variation between two measurements (mean 2.48 % and 1.35 % respectively, p < 0.05) and back-transformed 95 % limits of agreement (1.005-1.060 for FSE; 0.988-1.019 for CSE). Although FSE sequences are quicker and the total lesion volume measurements are similar to those obtained with CSE, the poorer reproducibility raises doubts about the use of FSE to replace CSE in clinical trials.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 25 条
[1]  
AHN SS, 1992, AM J NEURORADIOL, V13, P1169
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[4]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[5]  
DUQUETTE P, 1995, NEUROLOGY, V45, P1277
[6]   Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis - A comparison of techniques [J].
Filippi, M ;
Horsfield, MA ;
Bressi, S ;
Martinelli, V ;
Baratti, C ;
Reganati, P ;
Campi, A ;
Miller, DH ;
Comi, G .
BRAIN, 1995, 118 :1593-1600
[7]   CORRELATIONS BETWEEN CHANGES IN DISABILITY AND T-2-WEIGHTED BRAIN MRI ACTIVITY IN MULTIPLE-SCLEROSIS - A FOLLOW-UP-STUDY [J].
FILIPPI, M ;
PATY, DW ;
KAPPOS, L ;
BARKHOF, F ;
COMPSTON, DAS ;
THOMPSON, AJ ;
ZHAO, GJ ;
WILES, CM ;
MCDONALD, WI ;
MILLER, DH .
NEUROLOGY, 1995, 45 (02) :255-260
[8]   RESOLUTION-DEPENDENT ESTIMATES OF LESION VOLUMES IN MAGNETIC-RESONANCE-IMAGING STUDIES OF THE BRAIN IN MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
HORSFIELD, MA ;
CAMPI, A ;
MAMMI, S ;
PEREIRA, C ;
COMI, G .
ANNALS OF NEUROLOGY, 1995, 38 (05) :749-754
[9]  
FILIPPI M, 1996, P 4 SCI M INT SOC MA, V1, P171
[10]   Lesion volume measurement in multiple sclerosis: How important is accurate repositioning [J].
GawneCain, ML ;
Webb, S ;
Tofts, P ;
Miller, DH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :705-713