Simultaneous biosensing of ethanol and glucose with combined use of a rotating bioreactor and a stationary column reactor

被引:21
作者
Matsumoto, K [1 ]
Waki, K [1 ]
机构
[1] Kyushu Univ, Fac Agr, Dept Food Sci & Technol, Higashi Ku, Fukuoka 8128581, Japan
关键词
rotating bioreactor; immobilized enzyme; electrochemical detection; chemiluminescence detection; ethanol; glucose;
D O I
10.1016/S0003-2670(98)00675-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determination of ethanol with electrochemical detection and glucose with chemiluminescence detection was performed with combined use of a rotating bioreactor and a stationary column reactor. Continuous-flow/stopped-flow sample-reagent processing was proposed in this system. In electrochemical detection of ethanol, when a sample was injected and arrived just above the rotating bioreactor, the working solution was stopped for a certain period. The rate of increase of oxidation current of hydrogen peroxide which was produced with the ethanol/alcohol oxidase reaction was measured. In the chemiluminescence detection of glucose, the working solution was propelled again, and the glucose in the sample was passed through the glucose oxidase immobilized column. The hydrogen peroxide produced was measured by chemiluminescence with luminol/peroxidase. The method is applied to the determination of glucose (ca. 2%) and ethanol (13-16%) in alcoholic beverages. (C) 1999 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 14 条
[1]   COMPARATIVE-STUDIES ON DATA-COLLECTION AND DATA TREATMENT IN KINETIC-BASED DETERMINATIONS WITH 2 ROTATING BIOREACTOR AMPEROMETRIC DETECTION SYSTEMS [J].
BAEZA, JJB ;
MATSUMOTO, K ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :785-793
[2]  
BAEZA JJB, 1993, QUIM ANAL, V12, P12
[3]  
CALRK LC, 1989, ENZYME ELECTRODE
[4]   MONITORING GLUTAMINE IN ANIMAL-CELL CULTURES USING A CHEMILUMINESCENCE FIBER OPTIC BIOSENSOR [J].
CATTANEO, MV ;
LUONG, JHT .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (06) :659-665
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]   CONTINUOUS-FLOW CHEMILUMINESCENCE DETECTION COMPRISING A ROTATING REACTOR [J].
LAN, ZH ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :139-146
[7]   CONTINUOUS-FLOW SENSOR STRATEGY COMPRISING A ROTATING BIOREACTOR AND A STATIONARY RING AMPEROMETRIC DETECTOR [J].
MATSUMOTO, K ;
BAEZA, JJB ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :636-639
[8]  
MATSUMOTO K, 1993, ANAL CHEM, V65, P1558
[9]   CONTINUOUS-FLOW STOPPED-FLOW SYSTEM INCORPORATING 2 NOTATING BIOREACTORS IN TANDEM - APPLICATION TO THE DETERMINATION OF ALKALINE-PHOSPHATASE ACTIVITY IN SERUM [J].
RABA, J ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1485-1489
[10]   SPECTROPHOTOMETRIC CELL COMPRISING PARALLEL ROTATING AND STATIONARY BIOREACTORS - APPLICATION TO THE DETERMINATION OF GLUCOSE IN SERUM SAMPLES [J].
RABA, J ;
LI, SF ;
MOTTOLA, HA .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :299-305