Eliminating the interferences from TRIS buffer and SDS in protein analysis by fused-droplet electrospray ionization mass spectrometry

被引:80
作者
Shieh, IF [1 ]
Lee, CY [1 ]
Shiea, J [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung, Fukuoka 804, Taiwan
关键词
fused-droplet electrospray ionization; TRIS; SDS;
D O I
10.1021/pr049765m
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multiply charged protein ions were detected from the solutions containing a high concentration of tris(hydroxymethyl) aminomethane buffer (TRIS) and sodium dodecyl sulfate (SDS) using fused-droplet electrospray ionization mass spectrometry (FD-ESI/MS). The sample aerosols were generated at ambient temperature with a pneumatic nebulizer commonly used to produce sample aerosols in an atmospheric pressure chemical ionization (APCI) source. The aerosols were carried by nitrogen gas to the tip of a capillary where charged methanol droplets had been continuously generated by electrospraying an acidic methanol solution. The neutral sample aerosols then fused with the charged methanol droplets and electrospray ionization proceeded from the newly formed fused droplets to generate multiply charged protein ions. Because of its low solubility in methanol, TRIS molecules (concentration as high as 1 M) were efficiently excluded from the newly formed droplets and the protein ion signals were detected and observed in the mass spectra. To remove the interferences from SDS, equal moles of positively charged cetyltrimethylammonium bromide (CTAB) was added into the SDS containing sample solution to form the dodecyl sulfate-cetyltrimethylammonium ion pair (DS-CTA). The DS-CTA ion pair has a low polarity and solubility in methanol and is excluded from the fused droplet. Protein ions were still detected from the solution containing 10(-2) M of SDS.
引用
收藏
页码:606 / 612
页数:7
相关论文
共 41 条
[1]   Novel anionic copolymerized surfactants of mixed achiral and chiral surfactants as pseudostationary phases for micellar electrokinetic chromatography [J].
Akbay, C ;
Tarus, J ;
Gill, NL ;
Agbaria, RA ;
Warner, IM .
ELECTROPHORESIS, 2004, 25 (4-5) :758-765
[2]   In vitro characterization of PEGylated phospholipid micelles for improved drug solubilization:: Effects of PEG chain length and PC incorporation [J].
Ashok, B ;
Arleth, L ;
Hjelm, RP ;
Rubinstein, I ;
Önyüksel, H .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (10) :2476-2487
[3]   A microfluidic electrocapture device in sample preparation for protein analysis by MALDI mass spectrometry [J].
Astorga-Wells, J ;
Jörnvall, H ;
Bergman, T .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :5213-5219
[4]  
BUDAVARI S, 1989, MERCK INDEX, P9679
[5]  
CBENDAHL L, 2004, J ANAL ATOM SPECTROM, V19, P143
[6]   Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry [J].
Chang, DY ;
Lee, CC ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2465-2469
[7]  
CHEN CN, 2005, IN PRESS J MASS SPEC
[8]   BIRD (blackbody infrared radiative dissociation): Evolution, principles, and applications [J].
Dunbar, RC .
MASS SPECTROMETRY REVIEWS, 2004, 23 (02) :127-158
[9]  
DURST RA, 1972, CLIN CHEM, V18, P206
[10]   The use of micellar systems in the extraction and pre-concentration of organic pollutants in environmental samples [J].
Ferrera, ZS ;
Sanz, CP ;
Santana, CM ;
Rodríguez, JJS .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (07) :469-479