Eliminating the interferences from TRIS buffer and SDS in protein analysis by fused-droplet electrospray ionization mass spectrometry

被引:79
作者
Shieh, IF [1 ]
Lee, CY [1 ]
Shiea, J [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung, Fukuoka 804, Taiwan
关键词
fused-droplet electrospray ionization; TRIS; SDS;
D O I
10.1021/pr049765m
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multiply charged protein ions were detected from the solutions containing a high concentration of tris(hydroxymethyl) aminomethane buffer (TRIS) and sodium dodecyl sulfate (SDS) using fused-droplet electrospray ionization mass spectrometry (FD-ESI/MS). The sample aerosols were generated at ambient temperature with a pneumatic nebulizer commonly used to produce sample aerosols in an atmospheric pressure chemical ionization (APCI) source. The aerosols were carried by nitrogen gas to the tip of a capillary where charged methanol droplets had been continuously generated by electrospraying an acidic methanol solution. The neutral sample aerosols then fused with the charged methanol droplets and electrospray ionization proceeded from the newly formed fused droplets to generate multiply charged protein ions. Because of its low solubility in methanol, TRIS molecules (concentration as high as 1 M) were efficiently excluded from the newly formed droplets and the protein ion signals were detected and observed in the mass spectra. To remove the interferences from SDS, equal moles of positively charged cetyltrimethylammonium bromide (CTAB) was added into the SDS containing sample solution to form the dodecyl sulfate-cetyltrimethylammonium ion pair (DS-CTA). The DS-CTA ion pair has a low polarity and solubility in methanol and is excluded from the fused droplet. Protein ions were still detected from the solution containing 10(-2) M of SDS.
引用
收藏
页码:606 / 612
页数:7
相关论文
共 41 条
[31]  
Shia JT, 1997, J MASS SPECTROM, V32, P247, DOI 10.1002/(SICI)1096-9888(199702)32:2<247::AID-JMS476>3.3.CO
[32]  
2-4
[33]   Generating multiply charged protein ions by ultrasonic nebulization/multiple channel-electrospray ionization mass spectrometry [J].
Shiea, J ;
Chang, DY ;
Lin, CH ;
Jiang, SJ .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4983-4987
[34]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[35]   Chip-based solid-phase extraction pretreatment for direct electrospray mass spectrometry analysis using an array of monolithic columns in a polymeric substrate [J].
Tan, AM ;
Benetton, S ;
Henion, JD .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5504-5511
[36]   On-line SPE-RP-LC for the determination of insulin derivatives in biological matrices [J].
Visser, NFC ;
Lingeman, H ;
Irth, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (02) :295-309
[37]   Automated on-line ionic detergent removal from minute protein/peptide samples prior to liquid chromatography electrospray mass spectrometry [J].
Vissers, JPC ;
Hulst, WP ;
Chervet, JP ;
Snijders, HMJ ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02) :119-128
[38]  
WEBER K, 1969, J BIOL CHEM, V244, P4406
[39]   A microfabricated dialysis device for sample cleanup in electrospray ionization mass spectrometry [J].
Xu, NX ;
Lin, YH ;
Hofstadler, SA ;
Matson, D ;
Call, CJ ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1998, 70 (17) :3553-3556
[40]   Determination of monophosphate nucleotides by capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Yeh, CF ;
Jiang, SJ .
ANALYST, 2002, 127 (10) :1324-1327