Effects of changes in stopping-power ratios with field size on electron beam relative output factors

被引:22
作者
Zhang, GG [1 ]
Rogers, DWO
Cygler, JE
Mackie, TR
机构
[1] Carleton Univ, Ottawa, ON K1S 5B6, Canada
[2] NRC, Ottawa, ON, Canada
[3] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
[4] Ottawa Reg Canc Ctr, Ottawa, ON K1Y 4K7, Canada
[5] Univ Wisconsin, Madison, WI 53706 USA
关键词
D O I
10.1118/1.598351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stopping-power ratios are a function of held size and vary with accelerators. To investigate how these variations affect relative output factor measurements made using ion chambers for electron beams, especially for small fields, ((L) over bar/rho)(air)(water) is calculated using the Monte Carlo technique for different field sizes, beam energies, and accelerators and is compared to the data in TG-21 or TG-25, which are for mono-energetic broad beams. For very small field sizes defined by cutouts, if the change in ((L) over bar/rho)(air)(water) with d(max) is ignored (i.e., TG-25 is not carefully followed), there is an overestimate of relative output factors by up to 3%. Ignoring the field-size effect on stopping-power ratio adds an additional overestimate of up to one-half percent, and using mono-energetic stopping-power ratio data instead of realistic beam data gives another error, but in the opposite direction, of up to 0.7%. Due to the cancellation of these latter two errors, following TG-25 with ((L) over bar/rho)(air)(water) data for broad mono-energetic beams will give the correct answer for the ROF measurement within 0.4% compared to using ((L) over bar/rho)(air)(water) data for which the field-size effect is considered for realistic electron beams. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1711 / 1716
页数:6
相关论文
共 20 条
[1]   POLARITY EFFECT FOR VARIOUS IONIZATION CHAMBERS WITH MULTIPLE IRRADIATION CONDITIONS IN ELECTRON-BEAMS [J].
AGET, H ;
ROSENWALD, JC .
MEDICAL PHYSICS, 1991, 18 (01) :67-72
[2]   THE CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR DOSIMETRY OF ELECTRON-BEAMS - AN EXTENSION OF THE 1983 AAPM PROTOCOL REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-39 [J].
ALMOND, PR ;
ATTIX, FH ;
HUMPHRIES, LJ ;
KUBO, H ;
NATH, R ;
GOETSCH, S ;
ROGERS, DWO .
MEDICAL PHYSICS, 1994, 21 (08) :1251-1260
[3]  
Andreo P., 1987, ABSORBED DOSE DETERM
[4]  
[Anonymous], 1983, MED PHYS, V10, P741
[5]   R(50) as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry [J].
Burns, DT ;
Ding, GX ;
Rogers, DWO .
MEDICAL PHYSICS, 1996, 23 (03) :383-388
[6]   Practical approach to electron beam dosimetry at extended SSD [J].
Cygler, J ;
Li, XA ;
Ding, GX ;
Lawrence, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1505-1514
[7]   CALCULATION OF STOPPING POWER RATIOS USING REALISTIC CLINICAL ELECTRON-BEAMS [J].
DING, GX ;
ROGERS, DWO ;
MACKIE, TR .
MEDICAL PHYSICS, 1995, 22 (05) :489-501
[8]   ION RECOMBINATION CORRECTIONS FOR PLANE-PARALLEL AND THIMBLE CHAMBERS IN ELECTRON AND PHOTON RADIATION [J].
HAVERCROFT, JM ;
KLEVENHAGEN, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01) :25-38
[9]  
ICRU, 1984, 37 ICRU
[10]  
Johansson KA, 1977, IAEA S P VIENN, P243