MDCT evaluation of the coronary arteries, 2004: How we do it - Data acquisition, postprocessing, display, and interpretation

被引:33
作者
Lawler, LP [1 ]
Pannu, HK [1 ]
Fishman, EK [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
D O I
10.2214/ajr.184.5.01841402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Cardiac CT is rapidly becoming part of clinical practice. The objective of this article is to discuss and illustrate the current practice of coronary artery MDCT, including data acquisition, postprocessing, image display, and interpretation. The practice described reflects our experince with a series of patients referred in routine clinical practice. CONCLUSION. The reader should gain an insight into the current clinical application of coronary artery CT.
引用
收藏
页码:1402 / 1412
页数:11
相关论文
共 26 条
[11]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[12]   Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Heuschmid, M ;
Georg, C ;
Ohnesorge, B ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2001, 221 (03) :683-688
[13]   Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography [J].
Lawler, LP ;
Fishman, EK .
RADIOGRAPHICS, 2001, 21 (05) :1257-1273
[14]   Evaluation of electron beam tomographic coronary arteriography with three-dimensional reconstruction in healthy subjects [J].
Lu, B ;
Dai, RP ;
Bai, H ;
He, S ;
Jing, BL ;
Zhuang, N ;
Gao, RL ;
Yang, YJ ;
Chen, JL ;
Budoff, MJ .
ANGIOLOGY, 2000, 51 (11) :895-904
[15]   Effects of window and threshold levels on the accuracy of three-dimensional rendering techniques in coronary artery electron-beam CT angiography [J].
Lu, B ;
Dai, RP ;
Jiang, SL ;
Bal, H ;
He, S ;
Zhuang, N ;
Sun, XG ;
Budoff, MJ .
ACADEMIC RADIOLOGY, 2001, 8 (08) :754-761
[16]   Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT [J].
Mahnken, AH ;
Wildberger, JE ;
Sinha, AM ;
Dedden, K ;
Stanzel, S ;
Hoffmann, R ;
Schmitz-Rode, T ;
Günther, RW .
ACTA RADIOLOGICA, 2003, 44 (03) :302-309
[17]  
MCCLENNAN BL, 1991, RADIOL CLIN N AM, V29, P437
[18]   Multislice computed tomography cardiac imaging: Current status [J].
Morgan-Hughes, GJ ;
Marshall, AJ ;
Roobottom, CA .
CLINICAL RADIOLOGY, 2002, 57 (10) :872-882
[19]   Coronary angiography with multi-slice computed tomography [J].
Nieman, K ;
Oudkerk, M ;
Rensing, BJ ;
van Ooijen, P ;
Munne, A ;
van Geuns, RJ ;
de Feyter, PJ .
LANCET, 2001, 357 (9256) :599-603
[20]  
OHNESORGE BM, 2002, MULTI SLICE CT CARDI