A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images

被引:232
作者
Mahfouz, MR
Hoff, WA
Komistek, RD
Dennis, DA
机构
[1] Joint Univ Tennessee, UT Oak Ridge Natl Lab, Ctr Biomed Engn, Oak Ridge, TN 37831 USA
[2] Colorado Sch Mines, Golden, CO 80401 USA
[3] Rocky Mt Musculoskeletal Res Lab, Denver, CO 80222 USA
基金
美国国家科学基金会;
关键词
simulated annealing; 3-D to 2-D registration; TKA knee implants; X-ray fluoroscopy;
D O I
10.1109/TMI.2003.820027
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method was developed for registering three-dimensional knee implant models to single plane X-ray fluoroscopy images. We use a direct image-to-image similarity measure, taking advantage of the speed of modern computer graphics workstations to quickly render simulated (predicted) images. As a result, the method does not require an accurate segmentation of the implant silhouette in the image (which can be prone to errors). A robust optimization algorithm (simulated annealing) is used that can escape local minima and rind the global minimum (true solution). Although we focus on the analysis of total knee arthroplasty (TKA) in this paper, the method can be (and has been) applied to other implanted joints, including, but not limited to, hips, ankles, and temporomandibular joints. Convergence tests on an in vivo image show that the registration method can reliably find poses that are very close to the optimal (i.e., within 0.4degrees and 0.1 mm), even from starting poses with large initial errors. However, the precision of translation measurement in the Z (out-of-plane) direction is not as good. We also show that the method is robust with respect to image noise and occlusions. However, a small amount of user supervision and intervention is necessary to detect cases when the optimization algorithm falls into a local minimum. Intervention is required less than 5% of the time when the initial starting pose is reasonably close to the correct answer, but up to 50% of the time when the initial starting pose is far away. Finally, extensive evaluations were performed on cadaver images to determine accuracy of relative pose measurement. Comparing against data derived from an optical sensor as a "gold standard," the overall root-mean-square error of the registration method was approximately 1.5degrees and 0.65 mm (although Z translation error was higher). However, uncertainty in the optical sensor data may account for a large part of the observed error.
引用
收藏
页码:1561 / 1574
页数:14
相关论文
共 49 条
[21]   Tibiofemoral movement 4: changes of axial tibial rotation caused by forced rotation at the weight-bearing knee studied by RSA [J].
Karrholm, J ;
Brandsson, S ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1201-1203
[22]   OPTIMIZATION BY SIMULATED ANNEALING [J].
KIRKPATRICK, S ;
GELATT, CD ;
VECCHI, MP .
SCIENCE, 1983, 220 (4598) :671-680
[23]   ON RECOGNIZING AND POSITIONING CURVED 3-D OBJECTS FROM IMAGE CONTOURS [J].
KRIEGMAN, DJ ;
PONCE, J .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (12) :1127-1137
[24]   3-DIMENSIONAL KINEMATICS OF THE HUMAN KNEE DURING WALKING [J].
LAFORTUNE, MA ;
CAVANAGH, PR ;
SOMMER, HJ ;
KALENAK, A .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :347-357
[25]  
Landy MM, 1988, J ARTHROPLASTY S, VS3, P73
[26]   RECOVERING THE POSITION AND ORIENTATION OF FREE-FORM OBJECTS FROM IMAGE CONTOURS USING 3D DISTANCE MAPS [J].
LAVALLEE, S ;
SZELISKI, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1995, 17 (04) :378-390
[27]   A PATIENT-TO-COMPUTED-TOMOGRAPHY IMAGE REGISTRATION METHOD BASED ON DIGITALLY RECONSTRUCTED RADIOGRAPHS [J].
LEMIEUX, L ;
JAGOE, R ;
FISH, DR ;
KITCHEN, ND ;
THOMAS, DGT .
MEDICAL PHYSICS, 1994, 21 (11) :1749-1760
[28]   FITTING PARAMETERIZED 3-DIMENSIONAL MODELS TO IMAGES [J].
LOWE, DG .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1991, 13 (05) :441-450
[29]  
MAHFOUZ M, 2002, THESIS ENG DIV COLOR
[30]  
Matsopoulos G K, 1999, IEEE Trans Inf Technol Biomed, V3, P47, DOI 10.1109/4233.748975