The application of capillary pumped loop for cooling of electronic components

被引:81
作者
Chen, PC [1 ]
Lin, WK [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Engn & Syst, Hsinchu, Taiwan
关键词
capillary pumped loop; natural circulation; CPU;
D O I
10.1016/S1359-4311(01)00045-X
中图分类号
O414.1 [热力学];
学科分类号
摘要
A capillary pumped loop (CPL) can be used as a heat transferring device for cooling electronic chips (such as CPU of a personal computer or notebook), The purpose of the paper is to investigate the parameters affecting the CPL. The thermal transport characteristics of CPL are obtained from experimental results. A 4.2 x 3.8 x 0.8 cm(3) CPL was designed for the experiments. The results indicate that: (1) the device is capable of dissipating 40 W of thermal energy and keeping the chip surface temperature under 100 degreesC; (2) the device can transfer heat from the evaporator to the condenser through natural circulation (i.e., without any external driving forces) if the relative height difference between the evaporator and condenser is greater than 1 cm. Some transport phenomena of the working fluid and the heat transfer characteristics of the loop were observed in the experiments and are discussed in detail below. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1739 / 1754
页数:16
相关论文
共 9 条
[1]
EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF A CAPILLARY PUMPED LOOP [J].
DICKEY, JT ;
PETERSON, GP .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1994, 8 (03) :602-607
[2]
Investigation of a heat pipe array for convective cooling [J].
Howard, AH ;
Peterson, GP .
JOURNAL OF ELECTRONIC PACKAGING, 1995, 117 (03) :208-214
[3]
Evaporative heat transfer in a capillary structure heated by a grooved block [J].
Liao, Q ;
Zhao, TS .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1999, 13 (01) :126-133
[4]
EXPERIMENTAL RESULTS FOR CAPILLARY LOOPED PIPE APPLIED TO DIRECT COOLING METHOD [J].
MIYASAKA, A ;
NAKAJIMA, K ;
TSUNODA, H .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1995, 9 (01) :96-100
[5]
Experimental and theoretical investigation of a capillary pumped loop with a porous element in the condenser [J].
Muraoka, I ;
Ramos, FM ;
Vlassov, VV .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1998, 25 (08) :1085-1094
[6]
NGUYEN T, 2000, P 16 ANN IEEE SEM TH, P76
[7]
North M. T., 1993, Transactions of the ASME. Journal of Electronic Packaging, V115, P112, DOI 10.1115/1.2909290
[8]
SAUCIUC I, 2000, P 16 IEEE SEM THERM, P27
[9]
Xie H, 1996, IEEE T COMPON PACK A, V19, P54