Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null

被引:102
作者
Dowell, Nicholas G. [1 ]
Tofts, Paul S. [1 ]
机构
[1] UCL, Inst Neurol, NMR Res Unit, London WC1N 3BG, England
关键词
RF mapping; inhomogeneity; in vivo; absolute flip angle;
D O I
10.1002/mrm.21368
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
RF field B(1) nonuniformity is the largest cause of error in the quantitative measurement of many clinically relevant parameters in MR images and spectra. Knowledge of the absolute flip angles at every region will improve the accuracy and precision of such parameters. This method uses the 180 degrees signal null to construct a flip angle map of the entire brain in less than 4 min, independent of T(1), T(2), and proton density. Three spoiled gradient echo volume acquisitions of the whole brain were made with three different flip angles. The optimum choice of flip angles was determined to be 145 degrees, 180 degrees, and 215 degrees. Linear regression analysis was used to determine the nominal (system calibrated) flip angle required for a signal null at every pixel and thence determine the absolute flip angle at that location. The experiment utilizes an existing MR sequence supplied by the scanner manufacturer. The technique is validated experimentally and a theoretical investigation into the optimum experimental parameters is presented.
引用
收藏
页码:622 / 630
页数:9
相关论文
共 28 条
[1]
RADIOFREQUENCY MAP OF AN NMR COIL BY IMAGING [J].
AKOKA, S ;
FRANCONI, F ;
SEGUIN, F ;
LEPAPE, A .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :437-441
[2]
A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI [J].
Barker, GJ ;
Simmons, A ;
Arridge, SR ;
Tofts, PS .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :59-67
[3]
Bosak E, 1999, MAGNET RESON MED, V41, P474, DOI 10.1002/(SICI)1522-2594(199903)41:3<474::AID-MRM8>3.0.CO
[4]
2-K
[5]
RAPID RADIOFREQUENCY CALIBRATION IN MRI [J].
CARLSON, JW ;
KRAMER, DM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :438-445
[6]
Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz [J].
Collins, CM ;
Yang, QX ;
Wang, JH ;
Zhang, X ;
Liu, H ;
Michaeli, S ;
Zhu, XH ;
Adriany, G ;
Vaughan, JT ;
Anderson, P ;
Merkle, H ;
Ugurbil, K ;
Smith, MB ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1026-1028
[7]
Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[8]
A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185
[9]
MEASUREMENTS OF MAGNETIC-FIELD VARIATIONS IN THE HUMAN BRAIN USING A 3D-FT MULTIPLE GRADIENT-ECHO TECHNIQUE [J].
ERICSSON, A ;
WEIS, J ;
HEMMINGSSON, A ;
WIKSTROM, M ;
SPERBER, GO .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :171-177
[10]
ERNST RR, 1997, PRINCIPLES NUCL MAGN, P119