Integrated gasification gas combined cycle plant with membrane reactors: Technological and economical analysis

被引:59
作者
Amelio, Mario
Morrone, Pietropaolo
Galucci, Fausto
Basile, Angelo
机构
[1] Univ Calabria, ITM, CNR, Inst Membrane Technol, I-87030 Arcavacata Di Rende, CS, Italy
[2] Univ Calabria, Dept Mech Engn, I-87030 Arcavacata Di Rende, CS, Italy
关键词
CO2; removal; capture; IGCC; membrane reactor;
D O I
10.1016/j.enconman.2007.04.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work, the capture and storage of carbon dioxide from the fossil fuel power plant have been considered. The main objective was to analyze the thermodynamic performances and the technological aspects of two integrated gasification gas combined cycle plants (IGCC), as well as to give a forecast of the investment costs for the plants and the resulting energy consumptions. The first plant considered is an IGCC* plant (integrated gasification gas combined cycle plant with traditional shift reactors) characterized by the traditional water gas shift reactors and a CO2 physical adsorption system followed by the power section. The second one is an IGCC(M) plant (integrated gasification gas combined cycle plant with membrane reactor) where the coal thermal input is the same as the first one, but the traditional shift reactors and the physical adsorption unit are replaced by catalytic palladium membrane reactors (CMR). In the present work, a mono-dimensional computational model of the membrane reactor was proposed to simulate and evaluate the capability of the IGCC(M) plant to capture carbon dioxide. The energetic performances, efficiency and net power of the IGCC* and IGCC(M) plants were, thus, compared, assuming as standard a traditional IGCC plant without carbon dioxide capture. The economical aspects of the three plants were compared through an economical analysis. Since the IGCC* and IGCC(M) plants have additional costs related to the capture and disposal of the carbon dioxide, a Carbon Tax (adopted in some countries like Sweden) proportional to the number of kilograms of carbon dioxide released in the environment was, assumed. According to the economical analysis, the IGCC(M) plant proved to be more convenient than the IGCC* one. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2680 / 2693
页数:14
相关论文
共 36 条
  • [31] PODOLSKI WF, 1974, IND ENG CHEM PROC DD, V13, P415, DOI 10.1021/i260052a021
  • [32] COMBINED-CYCLE POWER-PLANT WITH INTEGRATED COAL-GASIFICATION, CO SHIFT AND CO2 WASHING
    PRUSCHEK, R
    OELJEKLAUS, G
    BRAND, V
    HAUPT, G
    ZIMMERMANN, G
    RIBBERINK, JS
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) : 797 - 800
  • [33] The effect of air exposure on palladium-copper composite membranes
    Roa, F
    Way, JD
    [J]. APPLIED SURFACE SCIENCE, 2005, 240 (1-4) : 85 - 104
  • [34] Preparation and characterization of Pd-Cu composite membranes for hydrogen separation
    Roa, F
    Way, JD
    McCormick, RL
    Paglieri, SN
    [J]. CHEMICAL ENGINEERING JOURNAL, 2003, 93 (01) : 11 - 22
  • [35] FEASIBILITY OF POLYMER MEMBRANES FOR CARBON-DIOXIDE RECOVERY FROM FLUE-GASES
    VANDERSLUIJS, JP
    HENDRIKS, CA
    BLOK, K
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (5-8) : 429 - 436
  • [36] LIFE-CYCLE ANALYSIS OF FOSSIL POWER-PLANT WITH CO2 RECOVERY AND SEQUESTERING SYSTEM
    WAKU, H
    TAMURA, I
    INOUE, M
    AKAI, M
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) : 877 - 880