Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper

被引:163
作者
Lemos, VA [1 ]
Baliza, PX [1 ]
机构
[1] Univ Estadual Sudoeste BAhia, Lab Quim Analit, Nucl Quim Analit Bahia, BR-4520000 Jequie, BA, Brazil
关键词
preconcentration; synthesis; cadmium; copper; amberlite XAD-2; 2-aminothiophenol;
D O I
10.1016/j.talanta.2005.03.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new functionalized resin has been applied in an on-line preconcentration system for copper and cadmium determination. Amberlite XAD-2 was functionalized by coupling it to 2-aminothiophenol (AT-XAD) by means of an -N=N- spacer. This resin was packed in a minicolumn and used as sorbent in the on-line system. Metal ions were sorbed in the minicolumn, from which it could be eluted directly to the nebulizer-burner system of the flame atomic absorption spectrometer (FAAS). Elution of Cd(II) and Cu(II) from minicolumn can be made with 0.50 mol 1(-1) HCI or HNO3. The enrichment factors obtained were 28 (Cd) and 14 (Cu), for 60 s preconcentration time, and 74 (Cd) and 35 (Cu), if used 180 s preconcentration time. The proposed procedure allowed the determination of cadmium and copper with detection limits of 0.14 and 0.54 mu g 1(-1), respectively, when used preconcentration periods of 180 s. The effects of foreign ions on the adsorption of these metal ions are reported. The validation of the procedure was carried out by analysis of certified reference material. This procedure was applied to cadmium and copper determination in natural, drink and tap water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 46 条
[1]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[2]   Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[3]   ONLINE PRECONCENTRATION OF SILVER ON ACTIVATED ALUMINA AND DETERMINATION IN BOREHOLE WATER BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROPHOTOMETRY [J].
COETZEE, PP ;
TALJAARD, I ;
DEBEER, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (03) :201-204
[4]   Application of silica gel organofunctionalized with 3(1-imidazolyl)propyl in an on-line preconcentration system for the determination of copper by FAAS [J].
da Silva, EL ;
Martins, AO ;
Valentini, A ;
de Fávere, VT ;
Carasek, E .
TALANTA, 2004, 64 (01) :181-189
[5]   Use of Nb2O5-SiO2 in an automated on-line preconcentration system for determination of copper and cadmium by FAAS [J].
da Silva, EL ;
Ganzarolli, EM ;
Carasek, E .
TALANTA, 2004, 62 (04) :727-733
[6]   Sorption behaviour of lanthanum(III), neodymium(III), terbium(III), thorium(IV) and uranium(VI) on Amberlite XAD-4 resin functionalized with bicine ligands [J].
Dev, K ;
Pathak, R ;
Rao, GN .
TALANTA, 1999, 48 (03) :579-584
[7]   Polyurethane foams as solid chromogenic reagents for diffuse reflectance spectroscopy [J].
Dmitrienko, SG ;
Sviridova, OA ;
Pyatkova, LN ;
Senyavin, VM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :361-368
[8]   Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery [J].
dos Santos, WL ;
dos Santos, CMM ;
Costa, JLO ;
Andrade, HMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2004, 77 (02) :123-129
[9]   Application of three-variables Doehlert matrix for optimisation of an on-line pre-concentration system for zinc determination in natural water samples by flame atomic absorption spectrometry [J].
dos Santos, WNL ;
Santos, CMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :211-221
[10]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108