Application of silica gel organofunctionalized with 3(1-imidazolyl)propyl in an on-line preconcentration system for the determination of copper by FAAS

被引:59
作者
da Silva, EL [1 ]
Martins, AO [1 ]
Valentini, A [1 ]
de Fávere, VT [1 ]
Carasek, E [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
FAAS; on-line preconcentration; organofunctionalized silica gel;
D O I
10.1016/j.talanta.2004.02.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a new procedure for the determination of trace levels of copper(II) in an aqueous matrix, through flow injection (FI) on-line preconcentration with a minicolumn packed with silica gel modified with 3(1-imidazolyl)propyl groups. After the preconcentration stage, the analyte was eluted with a HNO3 solution and determined by flame atomic absorption spectrometry (FAAS). The measurements of the analytical signals were carried out as peak area and peak height with the objective of evaluating the most appropriate absorption measurement for the proposed method. Four procedures to calculate the experimental enrichment factor (EF) were also studied. For a preconcentration time of 90 s the enrichment factors found in this study varied between 19.5-25.8 and 36.2-42.2 for peak area and peak height, respectively. The precision of the proposed method was calculated for a solution containing 20 mug l(-1) of Cu(II), when 11.2 ml of solution was preconcentrated (n = 7), and their respective relative standard deviation (R.S.D.) values were 1.2 and 1.4% for peak area and peak height, respectively. The detection limits obtained were 0.4 and 0.2 mug l(-1) of Cu(II) for peak area and peak height, respectively, with a preconcentration time of 90 s. The on-line preconcentration system accuracy was evaluated through a recovery test on the aqueous samples and analysis of a certified material. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 36 条
[1]   Copper determination after FI on-line sorbent preconcentration using 1-nitroso-2-naphthol as a complexing reagent [J].
Ali, A ;
Ye, YX ;
Xu, GM ;
Yin, XF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (08) :642-646
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   Flame atomic absorption spectrometric determination of chromium(VI) by on-line preconcentration system using a PTFE packed column [J].
Anthemidis, AN ;
Zachariadis, GA ;
Kougoulis, JS ;
Stratis, JA .
TALANTA, 2002, 57 (01) :15-22
[4]   On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2001, 54 (05) :935-942
[5]   Use of Nb2O5-SiO2 in an automated on-line preconcentration system for determination of copper and cadmium by FAAS [J].
da Silva, EL ;
Ganzarolli, EM ;
Carasek, E .
TALANTA, 2004, 62 (04) :727-733
[6]   Sorption and preconcentration of metal ions in ethanol solution with a silica gel surface chemically modified with benzimidazole [J].
Dias, NL ;
Gushikem, Y ;
Polito, WL ;
Moreira, JC ;
Ehirim, EO .
TALANTA, 1995, 42 (11) :1625-1630
[7]   On-line preconcentration system for nickel determination in food samples by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
dos Santos, WNL ;
Lemos, VA .
ANALYTICA CHIMICA ACTA, 2001, 445 (02) :145-151
[8]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264
[9]   An automated on-line flow system for the pre-concentration and determination of lead by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
Lemos, VA ;
Santelli, RE ;
Ganzarolli, E ;
Curtius, AJ .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :41-46
[10]  
Fujiwara ST, 1999, J BRAZIL CHEM SOC, V10, P389