Contrast-enhanced dual-energy mammography using a scanned multislit system:: evaluation of a differential beam filtering technique

被引:13
作者
Bornefalk, Hans [1 ]
Hemmendorff, Magnus
Hjarn, Torbjorn
机构
[1] KTH, Dept Phys, SE-10691 Stockholm, Sweden
[2] Sectra Mamea AB, SE-16440 Kista, Sweden
关键词
D O I
10.1117/1.2727497
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a method for single-exposure, contrast-enhanced dual-energy imaging of tumors utilizing a scanned multislit system for digital mammography. This photon-counting system employs an array of silicon strip detectors mounted in an edge-on geometty. The line detectors and pre- and post-collimator slits are carefully aligned, and the multislit setup allows differential filtering of the x-ray beam in the pre-collimator slits. A high-energy image is constructed from those lines where the filter material has been chosen to harden the x-ray beam and the lowenergy image from the lines with a filter producing softer beams. Both images are obtained in the same scan, eliminating the need to change tube voltages and anode materials and minimizing the risk of motion artifacts. The method is illustrated on a purpose-built phantom, and logarithmic subtraction of the images produces images essentially free of anatomical clutter with the contrast-enhanced targets clearly visible. (C) 2007 SPIE and IS&T.
引用
收藏
页数:7
相关论文
共 19 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Scatter rejection in multislit digital mammography [J].
Åslund, M ;
Cederström, B ;
Lundqvist, M ;
Danielsson, M .
MEDICAL PHYSICS, 2006, 33 (04) :933-940
[3]  
Berger M., 1999, XCOM PHOTON CROSS SE
[4]   Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment [J].
Boone, JM .
RADIOLOGY, 1999, 213 (01) :23-37
[5]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[6]   Single-shot dual-energy subtraction mammography with electronic spectrum splitting: Feasibility [J].
Bornefalk, Hans ;
Lewin, John M. ;
Danielsson, Mats ;
Lundqvist, Mats .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (02) :275-278
[7]   Use of iodine-based contrast media in digital full-field mammography -: Initial experience [J].
Diekmann, F ;
Diekmann, S ;
Taupitz, M ;
Bick, U ;
Winzer, KJ ;
Hüttner, C ;
Muller, S ;
Jeunehomme, F ;
Hamm, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (03) :342-345
[8]   INCORPORATION OF SCATTERED RADIATION INTO DUAL-ENERGY RADIOLOGIC THEORY AND APPLICATION TO MAMMOGRAPHY [J].
JOHNS, PC ;
BEAUREGARD, RM .
MEDICAL PHYSICS, 1994, 21 (09) :1455-1462
[9]   DUAL-ENERGY MAMMOGRAPHY - INITIAL EXPERIMENTAL RESULTS [J].
JOHNS, PC ;
DROST, DJ ;
YAFFE, MJ ;
FENSTER, A .
MEDICAL PHYSICS, 1985, 12 (03) :297-304
[10]   THEORETICAL OPTIMIZATION OF DUAL-ENERGY X-RAY-IMAGING WITH APPLICATION TO MAMMOGRAPHY [J].
JOHNS, PC ;
YAFFE, MJ .
MEDICAL PHYSICS, 1985, 12 (03) :289-296